Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Megger

Megger TAU3 – 3-Phase Winding Resistance & Turns Ratio Tester

46 views
Delivery
  • High accuracy testing: TTR up to 62.5 V AC (±0.10%) and Winding Resistance up to 10 A DC (±0.2%)
  • Rugged portability: IP67 transit case and lightweight (15 kg) design optimized for field conditions
  • Advanced automation: Automatic vector validation, adaptive demagnetization, and one-touch OLTC testing
  • User-friendly interface: 10.1" touch screen with on-screen vectors and seamless data export to Excel/PowerDB
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Megger TAU3 Transformer Winding Analyser: Technical Features and Field Applications

The Megger TAU3 Transformer Winding Analyser is a high-performance, three-phase testing instrument designed for fast, reliable, and safe diagnostics on power, CT/PT, instrument, and distribution transformers. Engineered for field and substation environments, this analyser integrates multiple test functions into a single, portable unit. By utilizing a single lead connection and offering both AC and DC output modes, the TAU3 significantly reduces setup time while maintaining high accuracy. Professionals seeking to purchase this device often look for the Megger TAU3 price to evaluate the return on investment regarding efficiency and safety improvements. The unit’s rugged, wheeled design ensures it can withstand harsh conditions, while the guided setup via color-coded leads and on-screen vectors eliminates connection errors.

Technical Features and Field Applications of the Megger TAU3 Basic

Understanding the technical capabilities of the Megger TAU3 Basic is essential for transformer maintenance teams. This section details how its specific features translate into practical field applications, ensuring that technicians can diagnose issues quickly and accurately. When considering the Megger TAU3 price, it is important to note that the instrument’s comprehensive functionality replaces several standalone devices, offering significant value.

  • Unified AC/DC Testing: The analyser performs turns ratio (TTR) and excitation current tests without requiring the technician to switch lead types. This feature streamlines the testing process, reducing the time spent on-site and minimizing the risk of errors during lead reconfiguration.
  • High-Current Winding Resistance: With a capability of up to 10 A DC and a resistance accuracy of ±0.2 %, this function is critical for detecting loose connections and internal winding deformities. The high current output ensures rapid magnetization saturation, providing accurate resistance readings even on large power transformers.
  • Automatic Vector and Polarity Validation: Before each test begins, the device offers guided vector confirmation. This prevents incorrect test connections, a common source of inaccurate data, by verifying the polarity and phase sequence directly on the touch screen interface.
  • Adaptive Demagnetisation and Magnetic Balance Checks: After resistance testing, residual magnetism can remain in the transformer core. The TAU3 includes adaptive demagnetisation to ensure the core is neutralized, while magnetic balance checks help assess the overall health of the transformer core.
  • On-Load Tap Changer (OLTC) Testing: The unit features "make before break" continuity tests and one-touch OLTC operation for both AC and DC modes. This allows for detailed analysis of tap changer performance without interrupting the testing cycle, identifying arcing or contact wear issues.
  • Large, Bright Interface: A 10.1-inch high-brightness touch screen provides clear visibility in various lighting conditions. The color-coded leads and vector display match the transformer nameplate, making the setup intuitive for operators of all skill levels.
  • Export and Reporting Capabilities: Data management is streamlined through Excel export, PowerDB compatibility, and USB storage. The optional printer and custom application control allow for immediate on-site reporting, essential for compliance and client documentation.
  • Rugged and Portable Design: Built for field use, the analyser features a wheeled compact case, safety interlocks, emergency stop, and a key lock to prevent unauthorized access. This durability ensures the unit can be transported safely to remote substation locations.

Advantages of Single Lead Connection for Transformer Diagnostics

One of the most significant advantages of the Megger TAU3 Transformer Winding Analyser is its single lead connection capability. Traditionally, transformer testing requires multiple lead changes to switch between different measurement modes, which consumes valuable time and increases the likelihood of connection errors. By consolidating these functions, the TAU3 allows technicians to move seamlessly from turns ratio testing to excitation current measurements. This efficiency is a key selling point for buyers comparing the Megger TAU3 price against the labor costs associated with prolonged testing procedures. The reduction in setup time directly translates to increased productivity for maintenance crews.

Ensuring Safety and Accuracy in Substation Environments

Safety is a paramount concern when working in high-voltage substation environments, and the Megger TAU3 Basic addresses this with several built-in features. The instrument’s guided setup via on-screen vectors ensures that connections are verified before high voltage is applied, protecting both the operator and the equipment. Furthermore, the unit’s safety interlock and emergency stop features provide immediate shutdown capabilities in case of an anomaly. For those looking to buy the Megger TAU3, the assurance of safety compliance and data accuracy makes it a preferred choice over manual testing methods. 

Specification
Model TAU3 Basic
Turn-Ratio Testing (TTR) Up to 62.5 V AC; accuracy ±0.10 %; AC voltage ≤ 1000 V; extended ranges depending on model; phase vector validation before test
Winding Resistance (DC) Up to 10 A DC; ±0.2 % resistance accuracy
Vector / Polarity Validation Automatic vector check; guided setup to match transformer nameplate
Adaptive Demagnetisation Automatic after winding resistance tests to remove remanent magnetism
OLTC Continuity & Make-Before-Break One-touch OLTC testing for both AC and DC; automatic continuity checks
Display 10.1-inch high brightness touch screen; color coded leads; on-screen vectors
Data Export / Reporting Excel (XLSX), PowerDB-compatible; USB storage; optional USB printer
Lead Set & Connections Magnetic Kelvin clamps; extendable leads; safety banana plugs; operates with lengths up to 30 m :contentReference
Operating Temperature −20 °C to +50 °C :contentReference
Dimensions 558 × 287 × 190 mm approx. (55.8 × 28.7 × 19 cm)
Weight 15 kg approx. including wheels and case :contentReference
Power Input 100 - 240 V AC, 47 - 63 Hz, up to 1200 W 
Safety Standards IEC 61010-1:2010 + AMD1:2016; EMI/EMC IEC 61326-1:2012; RoHS-2; MIL-STD-810G shock/vibration 
Environmental Relative Humidity 0 - 90 % non-condensing; storage temp −30 °C to +70 °C; elevation up to 2000 m 
IP / Ingress Protection IP67 for transit case; rugged enclosure suitable for field conditions
Downloads
FAQs & How To

FAQs

A professional transformer diagnostic instrument used for winding resistance measurement and turns ratio verification.
Contact us through the store; we reply within one business day.
Yes, it is designed for accurate testing of medium and high-voltage power transformers.
Yes, it supports fast and accurate testing workflows ideal for project commissioning.
You can purchase it from uazon.ae, an authorized distribiutor offering genuine Megger equipment.

How To

Step-by-step guide for performing winding resistance and transformer turns ratio testing using the Megger TAU3.

Estimated Time: PT15M

Inspect the TAU3, verify correct test leads, ensure the transformer is isolated and properly grounded before testing.
Connect the phase leads to the transformer terminals following the indicated HV and LV connections for Winding Resistance and TTR testing.
Choose either winding resistance mode or turns ratio mode depending on the diagnostic task.
Start the automatic test sequence. The instrument will inject current or perform ratio calculations based on the selected mode.
Record the displayed readings and store the data as needed for inspection reports or engineering project documentation.