Fluke 125B Industrial ScopeMeter handheld Oscilloscopes

0.00 AED
In stock
Product Details
Brand: Fluke
Bandwidth: 20 MHz
Number of channels: 2
sample rate: 400 K samples
sensitivity: 5 mV to 200 V/div
Measurements: DC voltage (VDC), True-rms voltages (V ac and V ac+dc), Frequency (Hz), Peak, Duty cycle (PULSE), RPM, Pulse width (PULSE), Amperes (AMP), Temperature (TEMP) with optional temperature probe
Memory: 400 M samples Recorded Time
Display: 5.7-inch color active matrix TFT
Operating temperature: 0 to 40 °C (32 to 104 °F)
Storage Temperature: -20 to 60 °C (-4 to 140 °F)
Operating altitude: Operating at 3 km (10,000 feet)
Size: 259 x 132 x 55 mm (10.2 x 5.2 x 2.15 in)
Weight: 1.4 kg (3.2 lb) including battery pack
Power: Input voltage: 10 to 21 V DC Consumption: 5 W typical, Battery power: Rechargeable Li-Ion 10.8 V

Fluke 125B Industrial ScopeMeter handheld Oscilloscopes

The Fluke 125B Industrial ScopeMeter® is a versatile and robust tool designed for the rigorous demands of industrial electrical and electro-mechanical equipment troubleshooting and maintenance. This article delves into various aspects of the Fluke 125B, excluding specifications, benefits, user experiences, and availability details.

Integrated Functionality

One of the standout features of the Fluke 125B is its integration of multiple devices into a single compact unit. It combines the functions of an oscilloscope, a multimeter, and a high-speed recorder. This integration facilitates comprehensive testing and analysis, making it an indispensable tool for professionals in the field.

Applications in Industrial Settings

The Fluke 125B is tailored for application in industrial settings where electrical and electro-mechanical equipment play a crucial role. It is particularly useful for troubleshooting complex systems such as motor drives, automated production lines, and electrical installations. The device's ability to adapt to various signals makes it ideal for maintaining continuous operation and minimizing downtime in industrial environments.

Advanced Triggering Technology

The ScopeMeter is equipped with Fluke's proprietary Connect-and-View™ triggering technology. This advanced feature allows for automatic adjustment of settings to achieve stable waveform displays without manual intervention. It is particularly beneficial in environments where signal patterns vary, ensuring accurate readings and reducing setup time.

Data Analysis and Sharing Capabilities

Fluke 125B integrates seamlessly with the Fluke Connect® mobile app and FlukeView® software, enhancing its utility by enabling data analysis and archiving. These features allow for real-time collaboration among team members, who can view and share data remotely, facilitating quicker decision-making and problem resolution.

Durability and Design

Designed to withstand the harsh conditions typically found in industrial environments, the Fluke 125B is both compact and rugged. Its durability ensures reliable performance under challenging conditions, making it a reliable tool for field technicians who require robustness and reliability in their testing equipment.

Fluke 125B Specifications

Oscilloscope Mode (Vertical)

  • Frequency Response - DC Coupled
    • Without probes and test leads (with BB120): DC to 20 MHz (-3 dB)
    • With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)
    • With VP41 10:1 probe: DC to 20 MHz (-3 dB)
  • Frequency Response - AC Coupled (LF Roll Off)
    • Without probes and test leads: <10 Hz (-3 dB)
    • With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)
    • With VP41 10:1 probe: <10 Hz (-3 dB)
  • Rise Time, Excluding Probes, Test Leads: <17.5 ns
  • Input Impedance
    • Without probes and test leads: 1 MΩ/20 pF
    • With BB120: 1 MΩ/24 pF
    • With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF
    • With VP41 10:1 probe: 5 MΩ/15.5 pF
  • Sensitivity: 5 mV to 200 V/div
  • Analog Bandwidth Limiter: 10 kHz
  • Display Modes: A, -A, B, -B
  • Maximum Input Voltage A and B: Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage, With BB120: 600 Vrms
  • Maximum Floating Voltage, from any Terminal to Ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz

Oscilloscope Mode (Horizontal)

  • Scope Modes: Normal, single, roll
  • Ranges (Normal):
    • Equivalent sampling: 20 ns to 500 ns/div
    • Real time sampling: 1 μs to 5 s/div
    • Single (real time): 1 μs to 5 s/div
    • Roll (real time): 1 s to 60 s/div
  • Sampling Rate (for Both Channels Simultaneously):
    • Equivalent sampling (repetitive signals): up to 4 GS/s
    • Real time sampling 1 μs to 60 s/div: 40 MS/s

Trigger

  • Screen Update: Free run, on trigger
  • Source: A, B
  • Sensitivity A and B:
    • At DC to 5 MHz: 0.5 divisions or 5 mV
    • At 40 MHz: 4 divisions
  • Slope: Positive, negative

Advanced Scope Functions

  • Display Modes
    • Normal: Captures up to 25 ns glitches and displays analog-like persistence waveform
    • Smooth: Suppresses noise from a waveform
    • Glitch off: Does not capture glitches between samples
    • Envelope: Records and displays the minimum and maximum of waveforms over time
  • Auto Set (Connect-and-View): Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level

Cursor Readout

  • Sources: A, B
  • Single vertical line:
    • Average, min and max readout
    • Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
    • Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
    • Harmonics values in POWER QUALITY mode.
  • Dual vertical lines:
    • Peak-peak, time distance and reciprocal time distance readout
    • Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
  • Dual horizontal lines: High, low and peak-peak readout
  • Rise or fall time:
    • Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only
    • possible in single channel mode)
  • Accuracy: As oscilloscope accuracy

General Specifications

  • Waveform Display
    • Vertical: 10 div of 40 pixels
    • Horizontal: 12 div of 40 pixels
  • Maximum Input Voltage A and B
    • Direct on input or with leads: 600 Vrms CAT IV for derating
    • With banana-to BNC adapter BB120: 600 Vrms for derating
    • Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz
  • Display Type: 5.7" color active martrix TFT
  • Resolution: 640 x 480
  • Interface
    • Optically isolated: Transfer screen copies (bitmaps), settings and data
    • USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®
    • Wireless Radio with Adapter Frequency range: 2412 to 2462 MHz
  • Output power: <100 mW
  • Environmental: MIL-PRF-28800F, Class 2
  • Temperature
    • Battery operation: 32 to 104°F (0 to 40°C)
    • Power adapter operation: 32 to 122°F (0 to 50°C)
    • Storage: -4 to 140°F (-20 to 60°C) non-condensing
  • Humidity (Operating)
    • At 32 to 50°F (0 to 10°C): non-condensing
    • At 50 to 86°F (10 to 30°C): 95%
    • At 86 to 104°F (30 to 40°C): 75%
    • At 104 to 122°F (40 to 50°C): 45%
  • Altitude
    • Operating at 10,000' (3 km): CAT III 600 V
    • Operating at 6600' (2 km): CAT IV 600 V
    • Storage: 40,000' (12 km)
  • EMC Electromagnetic Compatibility: USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)
  • Enclosure Protection: IP51, ref: EN/IEC60529
  • Safety General:
    • IEC 61010-1: Pollution Degree 2
    • Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
  • Memory
    • Internal memory can store 20 data sets (screen waveform and setup)
    • Micro SD card slot with optional SD card (maximum size of 32 GB)
  • Power
    • External: Via power adapter BC430
    • Input voltage: 10 to 21 V DC Consumption: 5 W typical
    • Input connector: 5 mm jack
    • Internal: Via battery pack BP290
    • Battery power: Rechargeable Li-Ion 10.8 V
    • Operating time: 7 hours with 50 % backlight brightness
    • Charging time: 4 hours with test tool off, 7 hours with test tool on
  • Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging
  • Dimensions 10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
  • Weight 3.2 lbs (1.4 kg) including battery pack
Save this product for later
Share this product with your friends
Fluke 125B Industrial ScopeMeter handheld Oscilloscopes