Fluke 1735 Amazing Three-Phase Power Quality Logger

0.00 AED
In stock
Product Details
UPC: 095969344722
Brand: Fluke
Measurement Category: 600 V CAT II
Measurement Range: 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V AC
Resolution: 0.1 V
Frequency: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Sampling Rate: 10.24 kHz
Dimensions: 240 x 180 x 110 mm
Weight: 1.7 kg, including battery
Memory : 4 MB Flash memory, 3.5 MB for measuring data
Operating Temperature: 0°C to +40°C
Storage Temperature: -20°C to +60°C
Interfaces: RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Display: ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Power : NiMH battery-pack, with ac adapter (15 V to 20 V / 0.8 A)

Fluke 1735 Three-Phase Power Quality Logger

The Fluke 1735 Three-Phase Power Quality Logger is a versatile and reliable tool used for energy studies, basic power quality logging, and load studies. It is designed to measure the most critical three-phase power parameters, including RMS voltage, RMS current, phase angle, voltage events, voltage and current THD, voltage and current harmonics up to the 50th, active power, reactive power, power factor, active energy, reactive energy, and more. The device can log power and associated parameters for up to 45 days, monitor maximum power demand over user-defined averaging periods, and prove the benefit of efficiency improvements with energy consumption tests.

The Fluke 1735 Three-Phase Power Quality Logger is easy to set up and use, with included flexible current probes and a color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events. The device is suitable for various applications, including load studies, energy assessments, harmonics measurements, and voltage event capture. It is commonly used in petrochemical, oil and gas, pharmaceutical, water and wastewater, food and beverage, and power generation industries.

Fluke power logger 1735

The Fluke 1735 Three-Phase Power Quality Logger is an essential tool for professionals needing accurate and dependable power quality logging and energy analysis in their daily tasks. Built to withstand harsh environments, this rugged and compact device is designed to meet IEC 61010-1 600 V CAT III safety standards, featuring double or reinforced insulation, pollution degree 2, and IP65 protection standards according to EN60529 (excluding the battery compartment)

For more Details about the fluke 1735 power logger price and the payment methods Please contact our experts.

Fluke 1735 Specifications

General Display ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality Developed, designed and manufactured according to DIN ISO 9001
Memory 4 MB Flash memory, 3.5 MB for measuring data
Interface RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate 10.24 kHz
Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply NiMH battery-pack, with ac adapter (15 V to 20 V / 0.8 A)
Operation time with battery Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions 240 x 180 x 110 mm
Weight 1.7 kg, including battery
Ambient conditions Working temperature range -10°C to +50°C
Storage temperature range -20°C to +60°C
Operating temperature range 0°C to +40°C
Reference temperature range 23°C ±2°C
The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient ±0.1% of the measured value per°C from the reference
Intrinsic error Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class C1 (IEC 654-1) -5°C to +45°C, 5% to 95% RH, no dew
Housing Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMC Emission IEC/EN 61326-1:1997 class B
Immunity IEC/EN 61326-1:1997
Safety Safety IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
V-rms wye measurement Measuring range 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V AC
Intrinsic error ±(0.2% of measured value + 5 digits)
Operating error ±(0.5% of m. v. + 10 digit)
Resolution 0.1 V
V-rms delta measurement Measuring range 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V AC
Intrinsic error ±(0.2% of m. v. + 5 digit)
Operating error ±(0.5% of m. v. + 10 digit)
Resolution 0.1 V
A-rms measurement Flexi set I ranges 15 A/150 A/3000 A rms (at sine)
Current clamp ranges 1 A/10 A
Resolution 0.01 A
Ranges 150 A/3000 A and 1 A/10 A
Intrinsic error ±(0.5% of m. v. + 10 digit)
Operating error ±(1% of m. v. + 10 digit)
Ranges 15 A
Intrinsic error ±(0.5% of m. v. + 20 digit)
Operating error ±(1% of m. v. + 20 digit)
The errors of the current probes are not considered.
By using Flexi-set Flexi Set measuring error ±(2% of m. v. + 10 digit)
Position influence ±(3% of m. v. + 10 digit)
CF (typical) 2.83
When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- Reactive, D - Distorting Measuring range see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Specified error x (1-[PF])
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error ±(0.7% of m.v. +15 digit)
Resolution 1 kW
Operating error ±(1.5% of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error ±(0.7% of m.v. +15 digit)
Resolution 1 W to 10 W
Operating error ±(1.5% of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh) Intrinsic error ±(0.7% of m.v.+ F variation error* + 15 digit)
Resolution 1 W to 10 W
Operating error ±(1.5% of m.v. + F variation error 1 + 20 digit)
1. Frequency variation error
PF (Power factor) Range 0.000 to 1.000
Resolution 0.001
Accuracy ±1% of full scale
Frequency measurement Measuring range 46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error ±(0.2% of m. v. + 5 digit)
Operating error ±(0.5% of m. v.+ 10 digit)
Resolution 0.01 Hz
Harmonics Measuring range To 50th harmonic (< 50% of nom)
Accuracy Vm, Im, THDV, THDI IEC 61000-4-7:2002, Class II
Vm ≥ 3% Vn ±5% Vm
Vm < 3% Vnom ±0.15% Vnom
Im ≥ 10% Inom ±5% Im
Im < 10% Inom ±0 5% Inom
THDV for THD < 3% ±0.15% at Vnom
for THD ≥ 3% ±5% at Vnom
THDI for THD < 10% ±0.5% at Inom
for THD ≥ 10% ±5% at Inom
Vnom Normal voltage range
Inom Nominal current range
Vm and Im are measured values of harmonic m
Events Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error ±(1% of m.v. + 10 digit)
Operating error ±(2% of m.v. + 10 digit)
Resolution 0.1 V