finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)
Fluke 1736 and 1738 Fantastic Three-Phase Power Quality Logger
Fluke 1736 and 1738 Fantastic Three-Phase Power Quality Logger
The Fluke 1736 and Fluke 1738 Fantastic Three-Phase Power Quality Loggers stand at the forefront of advanced electrical monitoring, offering comprehensive insights into power quality parameters for three-phase systems.
Key Features:
1. Extensive Parameter Capture: Fluke 1736 and 1738 log over 500 power quality parameters, providing a thorough analysis of electrical systems. This extensive data capture ensures a detailed understanding of the power quality within a three-phase network.
Applications
These power quality loggers find applications in various industries, including manufacturing, where uninterrupted and high-quality power supply is critical for machinery and processes. Additionally, they are invaluable tools in troubleshooting and preventive maintenance.
The Fluke 1738 Three-Phase Power Quality Loggers offer a sophisticated solution for monitoring and analyzing power quality in three-phase systems. Their extensive parameter capture, Fluke Connect integration, and automatic data logging make them indispensable tools for professionals in the electrical and industrial sectors.
You can get the fluke 1738 software with its package in the time of delivery.
Fluke 1736 and Fluke 1738 Specifications
Accuracy | |||||
Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ||
Voltage | 1000 V | 0.1 V | ±(0.2% + 0.01%) | ||
Current: Direct input | i17xx-flex 1500 12" | 150 A | 0.1 A | ±(1% + 0.02%) | |
1500 A | 1:00 AM | ±(1% + 0.02%) | |||
i17xx-flex 3000 24" | 300 A | 1:00 AM | ±(1% + 0.03%) | ||
3000 A | 10:00 AM | ±(1% + 0.03%) | |||
i17xx-flex 6000 36" | 600 A | 1:00 AM | ±(1.5% + 0.03%) | ||
6000 A | 10:00 AM | ±(1.5% + 0.03%) | |||
i40s-EL clamp | 4:00 AM | 1 mA | ±(0.7% + 0.02%) | ||
40 A | 10 mA | ±(0.7% + 0.02%) | |||
Frequency | 42.5 Hz to 69 Hz | 0.01 Hz | ±(0.1%) | ||
Auxillary input | ±10 V dc | 0.1 mV | ±(0.2% + 0.02%) | ||
Voltage min/max | 1000 V | 0.1 V | ±(1% + 0.1%) | ||
Current min/max | Defined by accessory | Defined by accessory | ±(5% + 0.2%) | ||
THD on voltage | 1000% | 0.10% | ±0.5 | ||
THD on current | 1000% | 0.10% | ±0.5 | ||
Voltage harmonics 2nd to 50th | 1000 V | 0.1 V | ≥ 10 V: ±5% of reading | ||
< 10 V: ±0.5V | |||||
Current harmonics 2nd to 50th | Defined by accessory | Defined by accessory | ≥ 3% of current range: ±5% of reading | ||
< 3% of current range: ±0.15% of range | |||||
Unbalance | 100% | 0.10% | ±0.2 | ||
Intrinsic Uncertainty ±(% of reading +% of range)¹ | |||||
Parameter | Influence quantity | iFlex1500-12 | iFlex3000-24 | iFlex6000-36 | i40S-EL |
150 A / 1500 A | 300 A / 3000 A | 600 A / 6000 A | 4 A / 40 A | ||
Active Power P | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Active Energy E a | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent power S | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent Energy E ap | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Reactive power Q | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
Reactive Energy E r | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
Power Factor PF | - | ±0.025 | |||
Displacement Power Factor | - | ±0.025 | |||
DBF/cosϕ | - | ±0.025 | |||
Additional uncertainty in% of range¹ | V P-N >250 V | 0.02% | 0.02% | 0.02% | 0.02% |
¹Range = 1000 V x Irange | |||||
Reference conditions: | |||||
Environmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65% | |||||
Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10%. | |||||
Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10% of Irange | |||||
Primary conductor of clamps or Rogowski coil in center position | |||||
Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C | |||||
Electrical Specifications | |||||
Power Supply | |||||
Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit | ||||
100 V to 240 V using standard power cord (IEC 60320 C7) | |||||
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) | ||||
Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) | ||||
Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input | ||||
Mains power frequency | 50/60 Hz ±15% | ||||
Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable | ||||
On-battery runtime | Four hours in standard operating mode, up to 5.5 hours in power saving mode | ||||
Charging time | < 6 hours | ||||
Data Acquisition | |||||
Resolution | 16-bit synchronous sampling | ||||
Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency | ||||
Input signal frequency | 50/60 Hz (42.5 to 69 Hz) | ||||
Circuit types | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies) | ||||
Data storage | Internal flash memory (not user replaceable) | ||||
Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹ | ||||
¹The number of possible logging sessions and logging period depends on user requirements. | |||||
Basic Interval | |||||
Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy | ||||
Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min | ||||
Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms | ||||
Demand Interval (Energy Meter Mode) | |||||
Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy | ||||
Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off | ||||
Power Quality Measurements | |||||
Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD | ||||
Averaging interval | 10 min | ||||
Individual harmonics | 2nd to 50th harmonic | ||||
Total harmonic distortion | Calculated on 50 harmonics | ||||
Events | Voltage: dips, swells, interruptions, current: inrush current | ||||
Triggered recordings | Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30) | ||||
Waveform of voltage and current (1738) | |||||
Standards Compliance | |||||
Harmonics | IEC 61000-4-7: Class 1 | ||||
IEEE 519 (short time harmonics) | |||||
Power quality | IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device) | ||||
Power | IEEE 1459 | ||||
Power quality compliance | EN50160 (for measured parameters) | ||||
Interfaces | |||||
USB-A | File transfer via USB flash drive, firmware updates | ||||
Max. current: 120 mA | |||||
WiFi | File transfer and remote control via direct connection or WiFi infrastructure | ||||
Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738 or 1736 upgrade option) | ||||
USB-mini | Data download device to PC | ||||
Voltage Inputs | |||||
Number of inputs | 4 (3 phases and neutral) | ||||
Maximum input voltage | 1000 Vrms, CF 1.7 | ||||
Input impedance | 10 MΩ | ||||
Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz | ||||
Scaling | 1:1 and variable | ||||
Measurement category | 1000 V CAT III/600 V CAT IV | ||||
Current Inputs | |||||
Number of inputs | 4, mode selected automatically for attached sensor | ||||
Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 | ||||
Rogowski coil input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range | ||||
Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12" | ||||
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24" | |||||
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36" | |||||
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |||||
Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz | ||||
Scaling | 1:1 and variable | ||||
Auxiliary Inputs | |||||
Number of inputs | 2 | ||||
Input range | 0 to ±10 V dc, 1reading/s | ||||
Scale factor | Format: mx + b (gain and offset) user configurable | ||||
Displayed units | User configurable (7 characters, for example, °C, psi, or m/s) | ||||
Wireless Connection | |||||
Number of inputs | 2 | ||||
Supported modules | Fluke Connect® 3000 series | ||||
Acquisition | 1 reading/s | ||||
Environmental Specifications | |||||
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) | ||||
Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) | ||||
Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH | ||||
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH | |||||
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH | |||||
Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) | ||||
Storage altitude | 12,000m | ||||
Enclosure | IP50 in accordance with EN60529 | ||||
Vibration | MIL-T-28800E, Type 3, Class III, Style B | ||||
Safety | IEC 61010-1 | ||||
IEC Mains Input: Overvoltage Category II, Pollution Degree 2 | |||||
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 | |||||
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |||||
Electromagnetic compatibility | EN 61326-1: Industrial CISPR 11: Group 1, Class A | ||||
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |||||
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |||||
Temperature coefficient | 0.1 x accuracy specification/°C | ||||
General Specifications | |||||
Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel | ||||
Warranty | Instrument and power supply: Two-years (battery not included) | ||||
Accessories: one-year | |||||
Calibration cycle: two-years | |||||
Dimensions | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) | ||||
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) | |||||
Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) | |||||
Weight | Instrument: 1.1 kg (2.5 lb) | ||||
Power supply: 400 g (0.9 lb) | |||||
Tamper protection | Kensington lock slot | ||||
i17xx-flex 1500 12" Flexible Current Probe Specifications | |||||
Measuring range | 1 to 150 A ac/10 to 1500 A ac | ||||
Nondestructive current | 100 kA (50/60 Hz) | ||||
Intrinsic error at reference condition* | ±0.7% of reading | ||||
Accuracy 173x + iFlex | ±(1% of reading + 0.02% of range) | ||||
Temperature coefficient over operating temperature range | 0.05% of reading/°C 0.09% of reading/°F | ||||
Working voltage | 1000 V CAT III, 600 V CAT IV | ||||
Probe cable length | 305 mm (12 in) | ||||
Probe cable diameter | 7.5 mm (0.3 in) | ||||
Minimum bending radius | 38 mm (1.5 in) | ||||
Output cable length | 2 m (6.6 ft) | ||||
Weight | 115 g | ||||
Probe cable material | TPR | ||||
Coupling material | POM + ABS/PC | ||||
Output cable | TPR/PVC | ||||
Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) | ||||
Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) | ||||
Relative humidity, operating | 15% to 85% non-condensing | ||||
IP rating | IEC 60529:IP50 | ||||
Warranty | One-year |