UPC: 095969919012
Brand: Fluke
Number of Inputs: 4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Measurement Category: 1000 V CAT III / 600 V CAT IV
Measurement Range: ±8 kV
Bandwidth: DC to 30 kHz for PQ measurements, excluding transients
Resolution: 24-bit synchronous sampling
Frequency: 80 kS/s at 50/60 Hz
Scaling: 1:1, variable for use of potential transformers
Sampling Rate: 1 MS/s
Dimensions: 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in)
Weight: 4.6 lbs (2.1 kg)
Memory : 8 GB internal (expandable with microSD card)
Operating Temperature: -10 °C to 50 °C
Storage Temperature: -20 °C to 60 °C
Interfaces: Ethernet, USB type A, USB-C, WiFi/BLE module, LTE/4G module, GPS
Power : Li-Ion battery BP1770 with extended temperature range, customer replaceable

1773 power quality analyser

The Fluke 1773 Power Quality Analyzer is an advanced tool designed to simplify and enhance the process of power quality logging, troubleshooting, and analysis. This three-phase power quality analyzer is ideal for professionals seeking reliable data capture and comprehensive power quality assessment.

Key Features

  • High-Speed Transient Capture: The Fluke 1773 can capture transients up to 8 kV, allowing for detailed analysis of power quality events that may affect equipment performance and longevity.
  • Ease of Use: With instrument powering from the measurement circuit, the 1773 eliminates the need for additional power sources, simplifying setup and usage.
  • Comprehensive Data Logging: The analyzer logs voltage, current, and frequency (V/A/Hz) data, along with power parameters, dips, and swells, providing a complete picture of power quality.
  • Automatic Analysis: The Fluke 1773 features automated power quality health indicators, helping users quickly identify and troubleshoot issues.
  • Software Integration: The device integrates seamlessly with Fluke Energy Analyze Plus software, enabling easy download, analysis, and reporting of data for thorough evaluations.

Applications

The Fluke 1773 is perfect for a wide range of applications, including:
  • Industrial Facilities: Monitor and analyze power quality to ensure machinery operates efficiently and to prevent unexpected downtime.
  • Utility Companies: Assess power quality to meet regulatory requirements and ensure reliable service delivery.
  • Electrical Contractors: Troubleshoot and verify power quality issues on-site to provide accurate solutions for clients.

Fluke 1773 Power Quality Analyzer Specifications

Voltage inputs
Number of inputs 4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Measurement category 1000 V CAT III / 600 V CAT IV
Maximum input voltage 1000 V rms / 1000 V dc (1700 Vpk)
Nominal voltage range Wye and single phase: variable (50 V – 1000 V)
Delta: Variable (100 V – 1000 V)
IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V
Input impedance 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
Bandwidth DC to 30 kHz for PQ measurements, excluding transients
Resolution 24-bit synchronous sampling
Sampling frequency 80 kS/s at 50/60 Hz
Scaling 1:1, variable for use of potential transformers
Voltage transients
Measurement range ±8 kV
Sampling rate 1775: 1 MS/s
1777: 1 MS/s, 20 MS/s
Bandwidth DC to 1 MHz
Trigger Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz
Resolution 14-bit synchronous sampling
Current inputs
Number of inputs 4 inputs 3 phases and Neutral, range selected automatically to attached sensor
Range AC 1 A to 1500 A with i17XX-FLEX1500 12
1 A to 1500 A with i17XX-FLEX1500 24
3 A to 3000 A with i17XX-FLEX3000 24
6 A to 6000 A with i17XX-FLEX6000 36
40 mA to 40 A with clamp i40s-EL
4 A to 400 A with clamp i400s-EL
DC 20 A to 2000 A with 80i-2010-EL clamp
Bandwidth DC to 30 kHz
Resolution 24-bit synchronous sampling
Sampling frequency 80 kS/s at 50/60 Hz
Scaling 1:1, variable
Input voltage Clamp: 50 mV / 500 mV rms; CF 2.8
Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4
all at nominal probe range
Input impedance 11 kΩ
Aux inputs
Wired connection with 17XX-AUX adapter
Number of inputs 2
Input range Direct: 0 V dc to ± 10 V dc
0 V to 1000 V dc
Input impedance Direct: 2.92 MΩ
Scale factor Format: mx + b (gain and offset) user configurable
Displayed units User configurable (up to 8 characters, for example °C, psi, or m/s)
Data acquisition voltage and current
Input mains frequency DC, 50/60 Hz  15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz)
Topologies 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta
Data storage Fluke 1773/1775: 8 GB internal (expandable with microSD card)
Fluke 1777: 32 GB microSD card (installed)
Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.
The number of possible logging sessions and logging period depends on user requirements
Real time accuracy Internal: 3 ppm (0.26 s per day, 8 s per month)
NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC
GPS: < 1 ms absolute to UTC
Trend interval
Measured parameter See operator manual
Trend interval User selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging interval min/max values Voltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)
Aux, Power: 200 ms
Total harmonic distortion THD for voltage and current is calculated on 50 harmonics
Power quality measurements
Measured parameter See operator manual
Harmonics h0 … h50
% fund and RMS for voltage, current and power
Phase angles for voltage and current up to h11
Interharmonics ih0… ih50
% fund and RMS for voltage and current
Supraharmonics 2–9 kHz with 200 Hz bins
9–30 khz with 2 kHz bins
RMS for voltage and current
Harmonics measurement method Grouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.
Method selected automatically based on configured PQ standard or user configurable.
Total harmonic distortion Calculated on up to 50 harmonics (depends on selected PQ standard)
Mains signaling 2 frequencies in the range from 110 Hz to 3000 Hz
Events Voltage Dip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients
Current Inrush current
Triggered recordings Half cycle RMS of voltage and current for 10 s
Waveform of voltage and current for 10/12 cycles
Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s
Transients: Waveform of voltage
(Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts)
Standard compliance
Power IEEE 1459
Harmonics IEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics)
Flicker IEC 61000-4-15 Class F1
Power quality IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI
Power quality compliance EN 50160 + GOST + NEQUAL + NETCODE + FOL
Interfaces
Ethernet 1 Gbit/s 1000BASE-T
USB type A USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA
USB-C USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)
Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA
WiFi/BLE module1 802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode
Bluetooth 5.0/BLE
Antenna: Internal and external2
LTE/4G module3 LTE-A Cat 12
Worldwide LTE-A and UMTS/HSPA+ coverage
Antenna: External2
GPS MCX connector to attach a GNSS antenna for GPS/GLONASS2

1 Not in 177X/BASIC versions

2 Requires 5m extension cable, Fluke p/n 5263915

3 Availability and supported providers vary by country. Check with your local Fluke representative.

Parameter Range Resolution Intrinsic Accuracy at Reference Conditions
% of Reading + % of Full Scale
Voltage 1000 V 0.1 V 0.1 % of nominal voltage
in accordance with
IEC 61000-4-30 Class A1,2
  ±(0.04 % + 0.004 %)3
Voltage dips and swells - 0.1 V 0.2 % of Vnom1,2
Voltage transients ±8 kVpk - ±5 % +0.25 %)
Voltage harmonics/interharmonics 100% 0.1 % / 0.1 mV ≥1 % Vnom1:  ±2.5 % of rdg.
<1 % Vnom1:  ±0.025 Vnom
THD on voltage 100% 0.1 % / 0.1 V ±(2.5 % + 0.5 %)
Voltage distortions 2-9 kHz Max 100 V 0.1 mV ±(2.5 % + 0.1 V)
Voltage distortions 9-30 kHz Max 100 V 0.1 mV ±(2.5 % + 0.1 V)
Current With iFlex 1500 A, 150 A 0.01% ±(1 % + 0.02 %)
(Rogowski clamp mode) i17XX-FLEX1500 24 1500 A 0.1 A
With iFlex 3000 A, 300 A 0.01 A ±(1 % + 0.03 %)
i17XX-FLEX3000 24 3000 A 0.1 A
With iFlex 6000 A, 600 A 0.1 A ±(1.5 % + 0.03 %)
i17XX-FLEX6000 36 6000 A ######
With AC clamp 40 A, ###### 0.001 A ±(0.7 % + 0.02 %)
i40s-EL 40 A 0.01 A
With AC clamp 400 A, 40 A 0.01 A ±(2 % + 0.2 %)
i400s-EL 400 A 0.1 A  ±(0.7 % + 0.1 %)
With AC/DC clamp 200 A 0.01 A ±(0.8 % + 0.2 %)
2000 A, 80i-2010s-EL 2000 A 0.1 A
Current min/max 100% defined by accessory x2 of intrinsic accuracy
Current harmonics/interharmonics 100% 0.1 % / 0.01 A ≥3 % Inom:  ±2.5 % of rdg.4
<3 % Inom:  ±0.15 % of Inom
THD on current 100% 0.10% ±(2.5 % + 0.5 %)
Frequency 42.5 Hz … 69 Hz 0.001 Hz ±0.01 Hz
Voltage unbalance 100% 0.10% ±0.15 %
Current unbalance 100% 0.10% ±0.15 %
Flicker Pinst, Pst, Plt 0 to 20 0.01 5%
Mains signaling voltage Up to 3 kHz 0.1 V / 0.1 % 1-3 % Vnom: ±0.15 % of Vnom
0-15 % of Vnom 3-15 % Vnom: ±5 % of rdg.
AUX input ±10 V 0.1 mV ±(0.2 % + 0.05 %)
1 Nominal voltage in the range of 100 V to 690 V. Also known as Udin.
2 0 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x3
3 Only for calibration laboratories
4 With iFlex 1500A, I17XX-FLEX1500 24