Brand: Fluke
Temperature range: -20 °C to 650 °C (-4 °F to 1202 °F)
Field of view: 34 °H x 24 °V
Thermal sensitivity: ≤ 0.075 °C at 30 °C target temp (75 mK)

Fluke Ti300+ Thermal Camera

The Fluke Ti300+ empowers teams to detect issues early before they escalate into serious problems. It offers high resolution and precision, effectively highlighting temperature variations and showing gradual heat changes over time. Featuring LaserSharp™ AutoFocus, the Ti300+ guarantees sharp images with every capture. Utilizing a built-in laser distance meter, it accurately measures and displays the distance to the target on the camera screen, ensuring focused images at the touch of a button. This capability enhances safety by allowing teams to maintain a safe distance from operational equipment while obtaining precise temperature readings from in-focus images.

To effectively capture thermal images that highlight issues, it's crucial to be familiar with your equipment and discern the subtle distinctions between typical and abnormal operating temperatures. Confidence in obtaining accurate thermal images is key, and using a Fluke Ti300+ thermal camera with LaserSharp AutoFocus simplifies this process significantly. Additionally, a rugged thermal camera is essential for ensuring quality infrared images even in challenging conditions, including drops from heights of up to two meters.

Fluke Ti300+ Key Features

  • 320 x 240 resolution
  • 2 meter drop test
  • LaserSharp™ Auto Focus
  • Manual or automatic focus
  • Measure up to 650 °C
  • Subject to Export Control

Fluke Ti300+ Specifications

Key features
IFOV with standard lens (spatial resolution) 1.85 mRad, D:S 532:1
Detector resolution 320 x 240
SuperResolution No
Infrared Resolution 76,800 pixels
MultiSharp™ Focus No
LaserSharp® Auto Focus Yes, for consistently in-focus images
Laser distance meter Yes, calculates distance to the target for precisely focused images and displays distance on screen
Advanced manual focus Yes
Ruggedized touchscreen display 3.5 inch (landscape) 640 x 480 LCD
Rugged, ergonomic design for one-handed use Yes
Digital zoom No
Temperature measurement
Temperature measurement range (not calibrated below -10 °C) -20 °C to 650 °C (-4 °F to 1202 °F)
Accuracy ±2 °C or 2% (at 25 °C nominal, whichever is greater)
Thermal sensitivity (NETD)* ≤ 0.075 °C at 30 °C target temp (75 mK)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
*Best possible
Wireless connectivity
To PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)
Fluke Connect® app compatible Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing
Fluke Connect® Assets optional software Through the desktop, assign images to assets, easily compare measurement types in one location and create reports
Fluke Connect® Instant Upload Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC
Fluke Connect® tool compatible Yes*, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen
IR-Fusion® technology
Adds the context of the visible details to your infrared image
AutoBlend™ mode Min, Mid, Max IR plus full visible on camera; continously variable in software
Picture-In-Picture (PIP) Yes
Built-in digital camera (visible light) 5 MP
Lenses
Standard lens IFOV (spatial resolution) 1.85 mRad, D:S 532:1
Field of view 34 °H x 24 °V
Minimum focus distance 15 cm (approx. 6 in)
IR-Fusion® technology Picture-In-Picture and full screen
Optional 2x telephoto smart lens IFOV (spatial resolution) 0.93mRad, D:S 1529:1
Field of view 17 °H x 12 °V
Minimum focus distance 45 cm (approx. 18 in)
IR-Fusion® technology Picture-In-Picture and full screen
Optional 4x telephoto smart lens IFOV (spatial resolution) 0.46 mRad, D:S 2941:1
Field of view 6 °H x 4.5 °V
Minimum focus distance 1.5 m (approx. 60 in)
IR-Fusion® technology N/A
Optional wide-angle smart lens IFOV 2.62 mRad, D:S 377:1
Field of view 48 °H x 34 °V
Minimum focus distance 15 cm (approx. 6 in)
IR-Fusion® technology Full screen
Level and span Smooth auto and manual scaling
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
Data storage and image capture
Extensive memory options Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud™ for permanent storage
Image capture, review, save mechanism One-handed image capture,review, and save capability
Image file formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Memory review Thumbnail and fullscreen review
Software Full analysis and reporting software with access to the Fluke Connect system
Export file formats with SmartView® software Bitmap (.bmp), GIF, JPEG, PNG, TIFF
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required
IR-PhotoNotes™ Yes (2 images)
Text annotation Yes
Video recording No
File formats video No
Streaming video (remote display) No remote display through Fluke Connect
Remote control operation Remote display only through Fluke Connect with HDMI connection. No remote control.
Auto capture (temperature and interval) No
Battery
Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery life 2-3 hours per battery (*Actual life varies depending on settings and usage)
Battery charge time 2.5 hours to full charge
Battery charging system Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power saving User selectable sleep and power off modes
Color palettes
Standard palettes 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ palettes 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
General specifications
Frame rate 60 Hz or 9 Hz versions
Laser pointer Yes
LED light (torch) Yes
Color alarms (temperature alarms) High temperature, low temperature, and isotherms (within range)
Center-point temperature measurement Yes
Spot temperature Hot and cold spot markers
User-definable spot markers No
Center box No
Infrared spectral band 7.5 μm to 14 μm (long wave)
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F)
Relative humidity 10% to 95% non-condensing
Safety IEC 61010-1: Overvoltage category II, Pollution Degree 2
Electromagnetic compatibility IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A
Australian RCM IEC 61326-1
US FCC CFR 47, Part 15 Subpart B
Vibration 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) drop with standard lens
Size (H x W x L) 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
Weight (battery included) 1.04 kg (2.3 lb)
Enclosure rating IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available
Recommended calibration cycle Two-years (assumes normal operation and normal aging)