finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)
KYORITSU KEW 1062 DIGITAL MULTIMETER
Kyoritsu KEW 1062 Digital Multimeter
The KYORITSU KEW 1062 Digital Multimeter is a versatile and high-precision instrument designed for professionals in various fields, including electrical and electronics. With a range of features and measurement capabilities, this multimeter provides accurate readings for a wide array of electrical parameters.
The KYORITSU KEW 1062 Digital Multimeter is a reliable and versatile tool for professionals requiring accurate measurements in electrical and electronic applications. Its range of features, high precision, and safety considerations make it an indispensable instrument for various industries.
KYORITSU KEW 1062 DIGITAL MULTIMETER Applications
Electrical Troubleshooting:
- Ideal for diagnosing electrical issues by measuring voltage, current, and resistance in circuits.
Electronic Circuit Testing:
- Suitable for testing and troubleshooting electronic circuits in various devices and equipment.
Field Service:
- Handy for field service technicians working on a variety of electrical and electronic systems.
Quality Assurance:
- Applicable for quality assurance checks in manufacturing processes, ensuring that electrical parameters meet specified standards.
KYORITSU KEW 1062 Key Features
Versatile Measurement Functions:
- The KEW 1062 is equipped with versatile measurement functions, allowing users to measure AC/DC voltage, AC/DC current, resistance, frequency, capacitance, temperature, and more. This versatility makes it suitable for a broad range of applications.
High Measurement Accuracy:
- With high measurement accuracy, the multimeter ensures reliable and precise readings for various electrical parameters. This accuracy is essential for troubleshooting, maintenance, and quality assurance.
Large LCD Display:
- Featuring a large and clear LCD display, the multimeter provides easy-to-read measurement results. The display may also include backlighting for visibility in low-light conditions.
Auto-Ranging Function:
- The auto-ranging function simplifies the measurement process by automatically selecting the appropriate measurement range. This feature ensures accurate readings without the need for manual adjustments.
Data Hold Function:
- The data hold function allows users to freeze and hold the displayed measurement value. This is particularly useful when taking measurements in hard-to-reach locations.
Built-in Temperature Measurement:
- With a built-in temperature measurement function, the multimeter enables users to measure temperature, expanding its capabilities for HVAC and other temperature-sensitive applications.
Safety Features:
- Designed with safety in mind, the multimeter may include features such as overload protection and safety ratings to ensure the safety of both the operator and the equipment being tested.
KYORITSU KEW 1062 Specifications
Feature | Description |
Detection Mode | MEAN/RMS (switch) |
DC V | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]) ±0.02%rdg±2dgt (Basic accuracy) |
AC V [RMS] | 50.000/500.00mV/5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) ±0.4%rdg±30dgt (Basic accuracy) |
AC V [MEAN] | 50.000/500.00mV/5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) ±1%rdg±30dgt (Basic accuracy) |
DCV+ACV | 5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V]) ±0.5%rdg±10dgt (Basic accuracy) |
DC A | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±0.2%rdg±5dgt (Basic accuracy) |
AC A [RMS] | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±0.75%rdg±20dgt (Basic accuracy) |
AC A [MEAN] | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±1.5%rdg±20dgt (Basic accuracy) |
DCA+ACA | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±1%rdg±10dgt (Basic accuracy) |
Resistance | 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ ±0.05%rdg±2dgt (Basic accuracy) |
Low Power | 5.000/50.00/500.0kΩ/5.000MΩ ±0.2%rdg±3dgt (Basic accuracy) |
Continuity Buzzer | 500.0Ω (The buzzer turns on for resistances lower than 100±50Ω) |
Diode Test | 2.4000V ±1%rdg±2dgt (Open circuit voltage: <5V, Approx. 0.5mA Measuring Current) |
Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF ±1%rdg±5dgt (Basic accuracy) |
Frequency | 2.000 - 9.999/9.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz ±0.02%rdg±1dgt (Basic accuracy), DUTY 10 - 90% ±1%rdg |
Temperature | -200 - 1372ºC ±1%rdg±1.5ºC, -328 - 2501.6ºF ±1%rdg±2.0ºF (with the use of K-type Temperature probe) |
Measurement Functions | DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitance, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, Low Power-Ω |
Other Functions | Data Hold (D/H), Auto Hold (A/H), Peak Hold (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight |
Applicable Standards | IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC) |
Power Source | R6 (1.5V)×4 (Auto power off: approx. 20 minutes) |
Dimensions | 192(L)×90(W)×49(D) mm |
Weight | Approx. 560g (including batteries) |
Included Accessories | 7220A (Test leads), R6×4, Instruction manual, 8926 (Fuse [440mA/1000V])×1 (included), 8927 (Fuse [10A/1000V])×1 (included) |