Kyoritsu KEW 5020 Data Logger
1,567.00 AED
In stock
Product Details
Brand:
kyoritsu
Applicable standards:
IEC 61010-1:2001 CAT III 300V Pollution degree2
Dimensions:
111(L)×60(W)×42(D)mm
Weight:
265g
Possible measurement time:
Approx. 10 days
Low battery warning:
Battery mark display (in 4 levels)
Voltage range:
600.0V
Current range:
100.0/1000A
RMS measuring interval:
approx. 100ms
Measuring method:
True RMS
Number of input channel:
3ch
Rated max. working voltage:
AC 9.9Vrms, 14V peak value
Kyoritsu KEW 5020 Data Logger
The Kyoritsu KEW 5020 Data Logger is a sophisticated instrument designed for professionals in various fields requiring precise data monitoring and recording. With advanced features and reliable performance, this data logger enables users to track and analyze environmental conditions over extended periods.
The Kyoritsu KEW 5020 Data Logger is a reliable and versatile tool for professionals requiring continuous monitoring and recording of environmental parameters. Its advanced features, multiple sensor inputs, and user-friendly design make it an indispensable instrument for various applications.
Kyoritsu KEW 5020 Data Logger Applications :
Environmental Monitoring:
- Ideal for monitoring environmental conditions in various settings, including laboratories, warehouses, and manufacturing facilities.
HVAC System Performance:
- Applicable for assessing the performance of heating, ventilation, and air conditioning (HVAC) systems by monitoring temperature and humidity levels.
Research and Development:
- Valuable for research and development projects where continuous data tracking is essential for understanding changes and trends.
Quality Control:
- Suitable for quality control processes, ensuring that environmental parameters meet specified standards over time.
Kyoritsu KEW 5020 Data Logger Key Features :
Data Logging Capabilities:
- The KEW 5020 is equipped with data logging capabilities, allowing it to continuously record and store data over time. This feature is invaluable for monitoring trends and variations in environmental parameters.
Multiple Sensor Inputs:
- Featuring multiple sensor inputs, the data logger can simultaneously monitor various environmental parameters such as temperature, humidity, pressure, voltage, and more. This versatility makes it suitable for diverse applications.
High Data Storage Capacity:
- With ample data storage capacity, the logger can store a large volume of data points. This is crucial for long-term monitoring and ensures that users have access to comprehensive datasets for analysis.
User-Configurable Sampling Intervals:
- The data logger allows users to configure the sampling intervals based on the specific requirements of their monitoring applications. This flexibility ensures optimal data collection for different scenarios.
Real-Time Display:
- Some models may include a real-time display, providing users with instant access to current environmental conditions. This feature aids in quick assessments and on-the-spot decision-making.
USB Connectivity:
- Equipped with USB connectivity, the data logger allows for easy and efficient data transfer to external devices such as computers. This facilitates data analysis, reporting, and archival.
Battery Operation:
- The logger may operate on batteries, providing a portable and convenient solution for applications where continuous power sources may not be available.
Kyoritsu KEW 5020 Data Logger Specifications :
- Recording mode: Normal, Trigger, Capture, Power Quality Analysis
- Operating system: Successive Approximation
(CH1 single synchronized sampling) - Rated max. working voltage: AC 9.9Vrms, 14V peak value
- Number of input channel: 3ch
- Measuring method: True RMS
- RMS measuring interval: approx. 100ms
- Sampling interval: Normal/Trigger mode : approx. 1.65ms/CH
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)
P.Q.A mode : approx. 0.55ms
- Current range: 8146 (30A type) : 100.0/1000mA/10.00/30.0A
8147 (70A type) : 100.0/1000mA/10.00/70.0A
8148 (100A type) : 100.0/1000mA/10.00/100.0A
8121 (100A type) : 10.00/100.0A
8122 (500A type) : 50.00/500.0A
8123 (1000A type) : 100.0/1000A
8128/8135 (5A type) : 5.000A/(50.00A)
8127 (100A type) : 10.00A/100.0A
8126 (200A type) : 20.00A/200.0A
8125 (500A type) : 50.00A/500.0A
8124 (1000A type) : 100.0A/1000A
8130 (1000A type) : 100.0/1000A - Auto power off: Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)
- Voltage range: 8309 (600V type) : 600.0V
- Low battery warning : Battery mark display (in 4 levels)
- Over-range indication : "OL" mark is displayed when exceeding the measuring range
- Auto power off : Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)
- Possible measurement time : Approx. 10 days (with alkaline LR6 batteries)
- Applicable standards : IEC 61010-1:2001 CAT III 300V Pollution degree2
IEC 61326 (EMC standard)
- Dimensions : 111(L)×60(W)×42(D)mm
- Weight : Approx. 265g