finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)

Megger MIT481-2 Insulation And Continuity Tester

0.00 AED
In stock
Product Details
Brand: Megger
Insulation Range: 50 V, 100 V, 250 V, 500 V
DC voltage Range: 10 mV to 600 V
AC voltage Range: 0 mV to 600 V TRMS
Capacitance Range: 0.1 nF to 10 μF
Continuity testing Range: 0.01 Ω to 1.0 MΩ
Leakage Current: 10% ±3 digits
Input Overload Protection: The instruments meet EN 61010-1 (1995) to 600V phase to earth, Category IV.
Operating temperature: -10 to +55 °C
Storage temperature: -25 to +70 °C
Altitude: 2000 m
Dimensions: 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in)
Weight: 800 g (1.8 lb), 1.75 kg (3.86 lb) instrument and case)
Power: 6 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP), Alkaline 6 x 1,2 V, NiMH rechargeable cells may be used
Display: Analogue: 1 GΩ full scale
Short Circuit Current: 2 mA +0% -50% to EN 61557-2 (2007)

Megger MIT481-2

The Megger MIT481-2 Insulation and Continuity Tester is a versatile and reliable tool designed for telecommunications and cable testing. Here are some key features and benefits:

Key Features

  • High Insulation Test Range: The MIT481-2 offers insulation testing up to 500 V and can measure resistance up to 100 GΩ.
  • Three-Wire Connection: It supports a three-wire connection for A, B, and E (Tip, Ring, and Ground/Earth), allowing for comprehensive testing without the need to disconnect test leads.
  • Gated Voltage Access: This feature prevents accidental selection of high voltage, enhancing user safety.
  • Rechargeable Options: The tester can be recharged using mains or car charging options, making it convenient for field use.
  • Differential Measurement Capability: This allows for more accurate and reliable measurements.
  • 600 V AC/DC Voltage Measurement: The MIT481-2 can measure both AC and DC voltages up to 600 V.
  • Bluetooth® Data Transfer: This feature enables easy downloading and storage of test results.
  • IP54 Rating: The tester is weatherproof, making it suitable for use in various environmental conditions.

Applications

  • Telecommunications: Ideal for testing insulation and continuity in telecommunications cables.
  • Cable Testing: Suitable for testing various types of cables in different environments.
  • Field and Laboratory Use: Its rugged design and portability make it suitable for both field and laboratory environments.
The Megger MIT481-2 Insulation and Continuity Tester is an essential tool for professionals in telecommunications and cable testing, offering a combination of advanced features, safety, and convenience.

Megger MIT481-2 Specifications

Nominal test voltage: 50 V, 100 V, 250 V, 500 V
Insulation accuracy 50 Volts: 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ
100 Volts: 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ
250 Volts: 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ
500 Volts: 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ
Service Error: BS EN 61557-2 (2007). 50V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5%
100V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
250V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
500V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
Display range: Analogue: 1 GΩ full scale
Resolution: 0.1 kΩ
Short circuit/charge current: Short circuit/charge current: 2 mA +0% -50% to EN 61557-2 (2007)
Open circuit voltage insulation: 0% +2% ± 2 V
Test current: 1 mA at min. pass value of insulation to a maximum of 2 mA max.
EN61557 Operating range: 0.10 MΩ to 1.0 0GΩ
Leakage Current: 10% ±3 digits
Timer control: Countdown timer 60 second
Note: Above specifications only apply when high quality silicone leads are being used.
Continuity
Continuity range: 0.01 Ω to 1.0 MΩ
Continuity accuracy: ± 3% ± 2 digits (0 to 100 Ω); ±5% ±2 digits (>100 Ω- 500 kΩ); (>500 kΩ - 1 MΩ unspecified)
Service Error: BS EN 61557-4
(2007) - ± 2.0%, 0.1Ω - 2Ω ± 6.8%
Open circuit voltage: 5 V ± 1 V
Test current: 200 mA (–0 mA +20 mA); (0.01 Ω to 4 Ω)
Lead resistance: Nulling up to 10 Ω
Voltage range
Voltage range AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz)
Voltage range DC: 10 mV to 600 V
Volt range accuracy AC: ± 2% ± 2 digits
Volt range accuracy DC: ± 2% ± 2 digits
Service Error: BS EN 61557
Waveform: Unspecified range: 0 – 10 mV (15 to 400 Hz)
additional specifications apply: ±3% ± 2 digits >100 mV to 600 V TRMS; ±8% ± 2 digits 10 mV to 100 mV TRMS
Default voltmeter: Operates at > 25 volts ac or dc on any range except OFF
Frequency
Frequency measurement range 15 Hz - 400 Hz
Frequency measurement accuracy ±0.5% ± 1 digit
Capacitance measurement
Capacitance range: 0.1 nF to 10 μF
Accuracy: ± 5.0% ± 2 digits ( 1 nF-10 μF)
Cable coefficient: 40n F/ km to 70nF / km
Unit of measure: 50nF / km 50nF / km
Result storage
Storage capacity: >1000 test results
Power supply

Power supply 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline; 6 x 1.2 V NiMH rechargeable cells may be used
Battery life 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 500 V into 500 kΩ
Charger (Optional) 12-15 V dc (accessory interface)
Dimensions 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in)
Weight: 800 g
Weight (instrument and case): 1.75 kg (3.86 lb)
Fuse: Use only 2 x 500 mA (FF) 1000V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum. Glass fuses MUST NOT be fitted.
Safety protection: The instruments meet EN 61010
EMC In accordance with IEC 61326 including amendment No.1
Temperature co-efficient: <0,1% per °C up to 1 GΩ; <0,1% per °C per GΩ; above 1 GΩ
Environmental
Operating temperature range and humidity: -10 to +55 °C; 90% RH at 40 °C max.
Storage temperature range: -25 to +70 °C
Calibration temperature: +20 °C
Maximum altitude: 2000 m
IP rating: IP 54 IP 54
Save this product for later
Share this product with your friends
Megger MIT481-2 Insulation And Continuity Tester