finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)

Megger PAT320 Portable Appliance Tester

0.00 AED
In stock
Product Details

Introduction of Megger PAT320

For individuals looking for a reliable and easy-to-use tool with great productivity, the PAT320 is the perfect choice. It is ideal for customers who don't need a fully adjustable database of clients and results within the tester but still need a comprehensive range of operations for both automatic and manual testing of a wide diversity of electrical assets.

It has dedicated test buttons for easy access to various tests. The PAT320 is a great option if you're new to PAT testing or would rather not deal with the hassles of database administration.

Megger PAT320 Key Features

  • Simple manual or automatic testing
  • 230 V and 110 V operation
  • Bond testing at 25 A,10 A, and 200 mA
  • Full colour display
  • Tests portable RCDs and extension leads
  • Differential, touch, and substitute leakage testing
  • Pre-set test sequences for Class I, Class II, and extension leads
  • Flash Testing at 1.5 kV and 3 kV
  • Tests to DIN VDE 0701-0702

Megger PAT320 Specifications

FEATURE SPECIFICATION
Electrical Supply Range 230 V ±10% ±1 V @ 50 Hz ±10% ±0.1 Hz
Instrument Accuracy Accuracy not guaranteed outside specified supply frequencies
Bond Test (10 A and 25 A) Open circuit voltage: 9 V a.c. ±10% ±0.1 V (Supply: 230 V 50 Hz)
Earth bond resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 1.99 Ω)
Resolution: 10 mΩ (0 to 1.99 Ω)
Display range: 10 to 1.99 Ω
Continuity Test voltage: 4.0 V d.c. -0% +10
Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 19.99 Ω)
Resolution: 10 mΩ (1 to 19.99 Ω)
Display range: 0 to 19.99 Ω
Insulation Test (250 V & 500 V) Accuracy (230 V): ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
Resolution: 0.01 MΩ
Display range: 0 to 99.99 MΩ
Substitute Leakage Current Test voltage and frequency: 40 V a.c. ±10% @ nominal mains frequency
Accuracy: ±5% ±5 digits
Resolution: 0.01 mA
Display range: 0 to 19.99 mA
Leakage Current Test voltage: Nominal mains supply
Accuracy: ±5% ± 5 digits
Resolution: 0.01 mA
Display range: 0 to 19.99 mA
Touch Current Test Test voltage: Nominal main supply
Accuracy: ±5% ±5 digits
Resolution: 0.01 mA
Display range: 0.00 to 10 mA
Operational Test Test voltage: Nominal mains supply
VA Accuracy: ±5% ±10 digits (0 to 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)
Resolution: 1 VA
Display range: 0 to 3.99 KVA
Ext Lead Test Test performed: Bond insulation and polarity
Polarity test voltage: 12 V dc
Polarity outcomes: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C
Flash Test (PAT350) Voltage: 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II
Current: < 3.5 mA short circuit @ 253 V primary supply voltage
Accuracy: ±5% ±5 digits
Resolution: 0.01 mA
Display range: 0 to 3.0 mA
RCD Tests Voltage and frequency: Nominal mains supply
Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
Trip time accuracy: ±1% ±5 digits
Resolution: 0.1 ms
Display ranges: Various
Fuse Test Voltage: 3.3 V
Indicator: Audible beep if fuse is OK
Temperature and Humidity Operating: -10 to +50 °C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C
Storage: -20 to +60° C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C
Weight PAT310: 3.2 kg, PAT320: 4.9 kg, PAT350: 5.5 kg
Dimensions PAT320: 155mm (H) x 255 mm (W) x 320 mm (L)