finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)

Megger TTRU3 True 3 Phase Transformer Turns Ratiometer

0.00 AED
In stock
Product Details
Brand: Megger
Excitation Voltage : 3Ø, 1 - 48VAC, up to 250V on Primary
Test Frequency : 50-480Hz
Excitation Current Range : 0.1mA - 1A, Max 2A @ 48V
Turns Ratio Range : ±0.05% 0.8 - 1000, ±0.10% 1001 - 2000, ±0.30% 2001 - 15000, ±1% 15001 - 50000
Current (rms) accuracy : ± 1% ±0.1 mA
Safety/EMC/Vibration : IEC 61010-1:2010 + AMD1:2016, IEC 61326-1:2012, MIL-STD-810G
Temperature Range : Operating: -20°C to +50°C (-4°F to +122°F), Storage: -30°C to +70°C (-22°F to +158°F)
Relative humidity : 0-90%, non-condensing
Measurement Method : 3Ø Step-Up, 3Ø Step-Down, 1Ø Step-Up, 1Ø Step-Down
Dimensions: 406 x 304 x 254mm / 16 x 12 x 8in
Weight: 6.5kg / 14lbs

Megger TTRU3

The Megger TTRU3 is a state-of-the-art, true three-phase transformer turns ratio tester designed to provide highly accurate and efficient testing for transformers. Here are some key features and benefits of the TTRU3:

Key Features

  • Three-Phase Testing: The TTRU3 performs true three-phase turns ratio measurements using a patented step-up excitation method. This allows for simultaneous testing of all three phases, significantly reducing testing time1.
  • High Accuracy: It guarantees a transformer turns ratio accuracy of ±0.05%, ensuring reliable and precise measurements1.
  • Fast Testing: Capable of completing three-phase tests in less than 10 seconds, making it one of the fastest testers on the market1.
  • Versatile Applications: Suitable for testing a wide range of transformers, including phase-shifting and zigzag transformers1.
  • High Test Voltage: Can induce up to 250 V on the primary winding, overcoming voltage dependence issues seen in larger transformers1.
  • User-Friendly Interface: Features a 7-inch daylight-viewable touch screen display for easy operation and data visualization1.
  • Data Management: Allows for the storage of test results directly on the device, and results can be downloaded in Excel or PDF formats. It also supports remote control and data download via a computer1.
  • Portability: The TTRU3 is the smallest and lightest three-phase test set available, making it highly portable and convenient for field use1.

Applications

  • Substation Testing: Ensures the accurate performance of transformers in substations.
  • Manufacturing Quality Control: Used in transformer manufacturing for quality assurance.
  • Maintenance and Troubleshooting: Helps in diagnosing and maintaining transformers in various settings12.

Additional Features:

  • Automated OLTC Testing: Automates the On-Load Tap Changer (OLTC) test sequence with a single touch1.
  • Optional Printer: An optional 2-inch printer is available for hard copies of test results1.
  • Overall, the Megger TTRU3 is a powerful and efficient tool for anyone involved in transformer testing, offering unparalleled accuracy, speed, and ease of use.

Megger TTRU3 Specifications

Input Power 90-264VAC, 47-63Hz, 250VA Max
Output Voltage 3Ø, 1 - 48VAC, up to 250V on Primary
Frequency 50-480Hz
Current 0.1mA - 1A, Max 2A @ 48V
Turns Ratio Measurement Methods 3Ø Step-Up, 3Ø Step-Down, 1Ø Step-Up, 1Ø Step-Down
Turns Ratio Range and Accuracy Step-Down Excitation 25-48V ±0.05% 0.8 - 1000
±0.10% 1001 - 2000
Guaranteed accuracy from -20°C to +50°C ±0.30% 2001 - 15000
±1% 15001 - 50000
Step-Down Excitation 1-24V ±0.10% 0.8 - 1000
±0.20% 1001 - 2000
±0.60% 2001 - 15000
Step-Up Measurement 25-250V ±0.05% 0.8 - 200 (most Power Tx)
Step-Up Measurement 1-24V ±0.10% 0.8 - 200
Excitation Current Measurement Resolution 0.1mA 0.1mA - 100mA, 1mA 101-2000mA
Accuracy ± 1% ±0.1 mA
Frequency Measurement Resolution 0.1 Hz
Accuracy ±0.1% ±0.1 Hz
Transformer Phase Measurement Range 0 - 360 Degrees
Accuracy ± 0.05 Degrees
Resolution 0.01 Degrees
Weight 6.5kg / 14lbs
Dimensions 406 x 304 x 254mm / 16 x 12 x 8in
Environmental Operating -20°C to +50°C (-4°F to +122°F)
Storage -30°C to +70°C (-22°F to +158°F)
Relative Humidity 0-90%, non-condensing
Regulatory Safety IEC 61010-1:2010 + AMD1:2016
EMI/EMC IEC 61326-1:2012
RoHS2 EN50581
Vibration/Drop/Shock MIL-STD-810G
Touchscreen 180mm (7 in.), 800 x 480 Resolution, 1100 NITS
Transformer Testing Standards IEEE C57.152-2013, IEC 60076-1:2011, AS/NZS 6076 1:2014, CIGRE 445 2011
Case Rugged case with fold-out feet, canvas carrying bag for leads and accessories
Internal/External Data Storage Up to 2000 sets of 3-phase results internal storage, transferable via USB 2.0/3.0 thumb drive
Communication/Control Software 180mm (7in) built-in display running custom GUI, USB Interface for PC Control running custom GUI
Printer Output 51mm (2in) thermal printer, prints all measurement data displayed on GUI