Fluke 1663 Installation Multifunction Tester
0.00 AED
متوفر في المتجر
تفاصيل المنتج
UPC:
095969850131
Brand:
Fluke
AC voltage Range:
500 V
AC voltage Resolution:
0.1 V
Continuity Range:
20 Ω / 200 Ω / 2000 Ω
Continuity Resolution:
0.01 Ω / 0.1 Ω / 1 Ω
Insulation resistance Test voltage:
50-100-250-500-1000 V
Insulation resistance range:
20 MΩ / 50 MΩ / 100 MΩ / 200 MΩ / 500 MΩ / 1000 MΩ
Loop and line impedance:
10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω
Earth Resistance Range:
200 Ω / 2000 Ω
Dimentions:
10 x 25 x 12.5 cm
Weight :
1.3 Kg
Power:
Type AA, 6 ea.
IP rating:
IP40
Overvoltage:
CAT III / 500V; CAT IV 300V
Fluke 1663 Installation Multifunction Tester
The Fluke 1663 Installation Multifunction Tester is a versatile and advanced tool designed to meet the needs of professional installers. This multifunction tester delivers full-featured functionality and advanced measurement capabilities, making it an ideal choice for a wide range of applications in the electrical industry.
Key Features
The Fluke 1663 Installation Multifunction Tester offers a comprehensive set of features, including:
- AC voltage measurement with a range of 500 V and a resolution of 0.1 V
- Accuracy of 45 Hz – 66 Hz at 0.8% + 3
- Continuity testing (RLO) with a range of 20 Ω / 200 Ω / 2000 Ω and an open circuit voltage of >4 V
- Insulation resistance measurement (RISO) with test voltages of 50-100-250-500-1000 V
- Phase sequence indicator
- Compact and portable design with a size of 10 x 25 x 12.5 cm and a weight of 1.3 Kg
- Safety compliance with EN/IEC 61010-1 and EN/IEC 61010-2-034
- Overvoltage protection with CAT III / 500V and CAT IV 300V rating
Applications
The Fluke 1663 Multifunction Tester is suitable for various applications, including:
- Testing continuity at L-N, N-PE inputs
- Testing smooth dc sensitive RCDs (Type B)
- Testing earth resistance, voltage, and frequency
- Offering multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
- 6 mA RDC-DD testing for EV charging stations
In conclusion, the Fluke 1663 Installation Multifunction Tester is a high-quality and reliable instrument that meets the demanding requirements of professional installers. With its advanced features, compact design, and safety compliance, the Fluke 1663 is an indispensable tool for a wide range of electrical testing applications. Whether it's testing continuity, RCDs, earth resistance, or voltage and frequency, the Fluke 1663 Multifunction Tester delivers the performance and accuracy that professionals need to ensure the safety and reliability of electrical installations.
Fluke 1663 Installation Multifunction Tester Specifications
AC voltage measurement | ||||
Range | 500 V | |||
Resolution | 0.1 V | |||
Accuracy 45 Hz – 66 Hz | 0.8% + 3 | |||
Input impedance | 360 kΩ | |||
Overload protection | 660 V rms | |||
Continuity testing (RLO) | ||||
Range (autoranging) | 20 Ω / 200 Ω / 2000 Ω | |||
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |||
Open Circuit Voltage | >4 V | |||
Insulation resistance measurement (RISO) | ||||
Test voltages | 50-100-250-500-1000 V | |||
Accuracy of test voltage (at rated test current) | +10%, -0% | |||
Test voltage | 50 V | |||
100 V | ||||
250 V | ||||
500 V | ||||
1000 V | ||||
Insulation resistance range | 20 MΩ / 50 MΩ | |||
20 MΩ / 100 MΩ | ||||
20 MΩ / 200 MΩ | ||||
20 MΩ / 200 MΩ / 500 MΩ | ||||
20 MΩ / 200 MΩ / 1000 MΩ | ||||
Resolution | 0.01 MΩ / 0.1 MΩ | |||
0.01 MΩ / 0.1 MΩ | ||||
0.01 MΩ / 0.1 MΩ | ||||
0.01 MΩ / 0.1 MΩ / 1 MΩ | ||||
0.01 MΩ / 0.1 MΩ / 1 MΩ | ||||
Test current | 1 mA @ 50 kΩ | |||
1 mA @ 100 kΩ | ||||
1 mA @ 250 kΩ | ||||
1 mA @ 500 kΩ | ||||
1 mA @ 1 MΩ | ||||
Loop and line impedance (ZI) | ||||
Range | 10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω | |||
Resolution | 0.001 Ω/ 0.01 Ω/ 0.1 Ω/1 Ω | |||
Prospective earth fault current, PSC test | ||||
Range | 1000 A / 10 kA (50 kA) | |||
Resolution | 1 A / 0.1 kA | |||
Computation | Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. | |||
RCD testing, RCD types tested | ||||
RCD Type | AC¹ | |||
G²,S³ | ||||
Model 1663 | A4, AC¹, G²,S³ | |||
Model 1664 FC | A, AC, B5, S | |||
Notes | ¹Responds to AC | |||
²General, no delay | ||||
³Time delay | ||||
⁴Responds to pulsed signal | ||||
⁵Responds to smooth DC signal | ||||
Tripping speed test (ΔT) | ||||
Current settings¹ | 10-30-100-300-500-1000 mA – VAR | |||
10-30-100 mA | ||||
Multiplier | x ½, x 1 | |||
x 5 | ||||
VAR Mode Type B - 6, 60, 200 mA | ||||
Measurement range | RCD Type G | 310 ms | ||
50 ms | ||||
RCD Type S | 510 ms | |||
160 ms | ||||
EV / RDC-DD | 6 mA - 10s | |||
60 mA - 0.3s | ||||
200 mA - 0.1s | ||||
Notes | ¹1000 mA type AC only | |||
700 mA maximum type A in VAR mode | ||||
The VAR Mode at RCD type B (smooth DC currents) generates the test currents acc. to IEC 62955 for RCD type A-EV or RDC-DD (6/60/200 mA and ramp <2 to 6 mA). | ||||
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) | ||||
Current range | 30% to 110% of RCD rated current¹ | |||
<2 mA to 6 mA smooth DC³ | ||||
Step size | 10% of IΔN² | |||
Linear rising within 30 s | ||||
Dwell time | RCD Type G | 300 ms/step | ||
RCD Type S | 500 ms/step | |||
Measurement accuracy | ±5% | |||
Specified trip current ranges (EN 61008-1) | 50% to 100% for Type AC | |||
35% to 140% for Type A (>10 mA) | ||||
35% to 200% for Type A (≤10 mA) | ||||
50% to 200% for Type B | ||||
Notes | ¹30% to 150% for Type A IΔN > 10 mA | |||
30% to 210% for Type A IΔN = 10 mA | ||||
20% to 210% for Type B | ||||
²5% for Type B | ||||
³For RCD type A-EV/RDC-DD acc. to IEC 62955 | ||||
Earth Resistance Test (RE) | ||||
Range | 200 Ω / 2000 Ω | |||
Resolution | 0.1 Ω / 1Ω | |||
Frequency | 128 Hz | |||
Output Voltage | 25 V | |||
Phase Sequence Indication | ||||
Icon |
|
|||
General Specifications | ||||
Size (L x W x H) | 10 x 25 x 12.5 cm | |||
Weight (incl. batteries) | 1.3 Kg | |||
Battery size, quantity | Type AA, 6 ea. | |||
Sealing | IP-40 | |||
Safety | Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034 | |||
Overvoltage | CAT III / 500V; CAT IV 300V | |||
Performance | EN61557-1 to EN61557-7 and EN61557-10 |