مطلوب تأكيد نهائي من الدعم. بمجرد تقديم طلبك، يرجى انتظار التأكيد النهائي من الشركة. ( 97144476031)

Fluke 3000 FC/1AC2 Advanced Combo Kit

0.00 AED
متوفر في المتجر
تفاصيل المنتج
Brand: Fluke
AC Voltage Range: 1000 V
DC Voltage Range: 1000 V
AC Current Range: 400.0 mA
DC Current Range: 400.0 mA
AC Voltage Overload Protection: 1100 V RMS
DC Voltage Overload Protection: 1100 V RMS
Resistance Range: 50.00 MΩ
Capacitance Range: 9999 μF
Frequency Range : 99.99 kHz
Diode test: 2.000 V
Power: Three AA Alkaline batteries, NEDA 15A IEC LR6
Dimension: 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight: 340 g (12 oz)
Continuity buzzer: 600 Ω

Fluke 3000 FC/1AC2 Combo Kit

The Fluke 3000 FC/1AC2 Combo Kit epitomizes innovation and efficiency in the realm of electrical testing and measurement.
Wireless Connectivity: One of the standout features of the Fluke 3000 FC/1AC2 Combo Kit is its wireless connectivity capabilities. Utilizing Fluke Connect®, technicians can remotely monitor and log data from the multimeter using their smartphones or tablets. This wireless functionality enhances flexibility and convenience, particularly in challenging or hazardous environments.
True RMS Accuracy: Equipped with True RMS technology, the Fluke 3000 FC multimeter delivers accurate measurements even in non-linear electrical systems. This ensures reliability in diagnosing electrical issues across a wide range of applications, from industrial settings to residential installations.
Integrated Voltage Detector: The inclusion of the Fluke 1AC II non-contact voltage detector in the combo kit adds an extra layer of safety and efficiency to electrical work. With its ability to quickly identify the presence of voltage without physical contact, technicians can assess circuits swiftly, reducing the risk of electrical hazards.
User-Friendly Design: Designed with the end-user in mind, the Fluke 3000 FC/1AC2 Combo Kit boasts a user-friendly interface and ergonomic construction. The multimeter features a large digit display with an analog bargraph, ensuring readability even in dimly lit conditions. Additionally, the display backlight enhances visibility, further facilitating ease of use.
Versatile Application: Whether in industrial maintenance, HVAC troubleshooting, or residential electrical inspections, the Fluke 3000 FC/1AC2 Combo Kit offers versatile functionality to meet diverse needs. Its comprehensive set of measurement capabilities, combined with wireless connectivity and safety features, makes it a valuable asset for electricians, technicians, and maintenance professionals alike.

Fluke 3000 FC/1AC2 Combo Kit Specifications

AC Voltage
Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mV Range / resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / resolution 600 Ω / 1 Ω
Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω Range / resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF Range / resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC Range1 / resolution 60.00 mA / 0.01 mA
(45 Hz to 1 kHz) 400.0 mA3 / 0.1 mA
Accuracy 1.5% + 3
mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy1 0.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection 1100 V RMS
Input impedance (nominal) > 10 MΩ < 100 pF
Common mode rejection ratio > 120 dB at DC, 50 Hz or 60 Hz
(1 kΩ unbalance)
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 V RMS
Input impedance (nominal) > 10 MΩ < 100 pF
Common mode rejection ratio > 60 dB, DC to 60 Hz
(1 kΩ unbalance)
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 V RMS
Input impedance (nominal) > 10 MΩ < 100 pF
Common mode rejection ratio > 120 dB at DC, 50 Hz or 60 Hz
(1 kΩ unbalance)
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection 1100 V RMS
Input impedance (nominal) < 2.7 V DC
Full scale voltage to 6 MΩ < 0.7 V DC
Full scale voltage 50 MΩ < 0.9 V DC
Typical short circuit current < 350 mA
Overload protection 1100 V RMS
Input impedance (nominal) < 2.7 V DC
Full scale voltage to 6 MΩ 2.000 V DC
Full scale voltage 50 MΩ
Typical short circuit current < 1.1 mA
mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions ± 12 counts for changes > 350 mS in duration.
AC functions ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20m
Obstructed, sheetrock wall Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility EN 61326–1:2006, EN 61326–2–2:2006
EMI, RFI, EMC, RF ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety compliance ANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Warranty Three years
Not compatible with Fluke CNX test tools
حفظ هذا المنتج في وقت لاحق
شارك هذه المنتج مع أصدقائك
Fluke 3000 FC/1AC2 Advanced Combo Kit