Fluke 377 FC Clamp Meter with iFlex
Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex
The Fluke 377 FC TRMS clamp meter uses FieldSense™ technology to make inspections faster and safer without contact with live wires. You get accurate voltage and current measurements using the clamping jaws. Simply attach the black test lead to any electrical ground, place the clamping jaws around the lead, and watch reliable and accurate current and voltage values on the display.
Measure extremely high current with iFlex® probe
Use the included iFlex flexible current probe to measure AC current up to 2,500 A. The iFlex probe allows access to large conductors in tight spaces.
Complete 3-phase measurements in quick, easy steps
- Complete 3-phase voltage and current tests in 3 easy steps
- Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
- Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
- Phase rotation auto-calculated and shown on the Fluke Connect software
- No more hand-written notes or complicated math.
Easy to see, easy to use with included tools
Your job will get easier when you use the Fluke clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.
Record, analyze, share results with Fluke Connect® software
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.
Fluke 377 FC Specifications
General specifications | ||
General Maximum Voltage between any Terminal and Earth Ground | 1000 V | |
Battery | Type | 2 AA IEC LR6 alkaline |
Life | 200 hour | |
Display | Dual readout | |
Automatic Power Off | 20 minutes |
Electrical | ||||
AC Current: Jaw | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2 % ±5 digits (45 Hz to 66 Hz) | |||
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 |
AC Current: Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 1 A (≤2500 A) 0.1 A (≤999.9 A) | |||
Accuracy | 3 % ±5 digits (5 Hz to 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 |
DC Current | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2 % ±5 digits1 | |||
[1]When using the ZERO function to compensate for offsets |
AC Voltage: Field Sense | ||||
Range | 1000 V | |||
Resolution | 1 V (≤1000V) | |||
Accuracy | ≤4/0 AWG | 3 % ±5 digits (45 Hz to 66 Hz) | ||
≥4/0 AWG | 5 % ±5 digits (45 Hz to 66 Hz) |
AC Voltage: Test Leads | ||||
Range | 600.0 V 1000 V | |||
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
|||
Accuracy | 1 % ±5 digits (20 Hz to 500 Hz) |
DC Voltage | ||||
Range | 600.0 V 1000 V |
|||
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
|||
Accuracy | 1 % ±5 digits | |||
mV dc | ||||
Range | 500.0 mV | |||
Resolution | 0.1 mV | |||
Accuracy | 1 % ±5 digits | |||
Amps Frequency: Jaw | ||||
Range | 45 Hz to 66 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5 % ±5 digits | |||
Trigger Level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A |
|||
Amps Frequency: Flexible Current Probe | ||||
Range | 5.0 Hz to 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5 % ±5 digits | |||
Trigger Level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz,≥25 A |
|||
Resistance | ||||
Range | 60.00 kΩ 6000 Ω 600.0 Ω |
|||
Resolution | 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) |
|||
Accuracy | 1 % ±5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) |
|||
Accuracy | 1 % ±4 dig |