مطلوب تأكيد نهائي من الدعم. بمجرد تقديم طلبك، يرجى انتظار التأكيد النهائي من الشركة. ( 97144476031)
Fluke 4180 Precision IR Calibrators
0.00 AED
متوفر في المتجر
تفاصيل المنتج
Brand:
Fluke
Range:
(at 23°C ambient, 0.95 emissivity): -15°C to 120°C
Accuracy:
±0.40°C at –15°C, ±0.40°C at 0°C, ±0.50°C at 50°C, ±0.50°C at 100°C, ±0.55°C at 120°C
Stability:
±0.10°C at -15°C, ±0.05°C at 0°C, ±0.10°C at 120°C
Well diameter :
152.4 mm (6 in)
Heating time :
15 min: -15°C to 120°C,14 min: 23°C to 120°C
Cooling time :
15 min: 120°C to 23°C,20 min: 23°C to –15°C
Power :
115 V AC (±10%), 6.3 A,50/60 Hz, 630 W,230 V AC (±10%), 3.15 A,,50/60 Hz, 630 W
Dimensions:
356 x 241 x 216 mm (14 x 9.5 x 8.5 in)
Weight:
9.1 kg (20 lb)
Fluke 4180
The Fluke 4180 Series Precision Infrared Calibrators are high-performance, portable instruments designed to provide accurate and reliable calibration of infrared thermometers and thermal imagers. These calibrators offer a wide temperature range, exceptional stability, and advanced features that make them suitable for both field and laboratory applications.
Key Features
- Temperature Range: The Fluke 4180 covers the range from -15°C to 120°C (5°F to 248°F), while the 4181 extends the range from 35°C to 500°C (95°F to 932°F).
- Display Accuracy: The 4180 achieves accuracies as good as ±0.35°C (±0.63°F), while the 4181 maintains accuracy up to ±0.5°C (±0.9°F).
- Stability: Both models offer excellent stability, with the 4180 achieving ±0.05°C (±0.09°F) and the 4181 reaching ±0.1°C (±0.18°F).
- Large Target Size: The 152 mm (6 in) target size is designed to accommodate the field of view and calibration geometry requirements of common infrared thermometers.
- Radiometric Calibration: The calibrators are radiometrically calibrated, ensuring traceable and consistent results.
- Intuitive Interface: The LCD display continuously shows the current temperature, and the temperature can be easily set using the control buttons.
- Safety Features: The 4180/4181 Series includes a unique safety feature that illuminates when the target temperature is above 50°C, indicating when it is safe to handle the instrument.
Applications
- Calibration of infrared thermometers and thermal imagers
- Maintenance and testing of HVAC systems
- Quality control in manufacturing processes
- Research and development in temperature-related fields
The Fluke 4180 Series Precision Infrared Calibrators offer a combination of accuracy, stability, and versatility that makes them an essential tool for professionals working with infrared temperature measurement. With their wide temperature ranges, large target sizes, and radiometric calibration, these calibrators provide reliable and consistent results in both field and laboratory settings.
Fluke 4180 Specifications
Temperature range (@ 23°C ambient, 0.95 emissivity) | –15°C to 120°C |
Display accuracy1 | ±0.40°C at –15°C |
±0.40°C at 0°C | |
±0.50°C at 50°C | |
±0.50°C at 100°C | |
±0.55°C at 120°C | |
Stability | ±0.10°C at –15°C |
±0.05°C at 0°C | |
±0.10°C at 120°C | |
Uniformity (5.0 in dia of center of target)2 | ±0.15°C at –15°C |
±0.10°C at 0°C | |
±0.25°C at 120°C | |
Uniformity (2.0 in dia of center of target)2 | ±0.10°C at -15°C |
±0.10°C at 0°C | |
±0.20°C at 120°C | |
Heating time | 15 min: –15°C to 120°C |
14 min: 23°C to 120°C | |
Cooling time | 15 min: 120°C to 23°C |
20 min: 23°C to –15°C | |
Stabilization time | 10 minutes |
Nominal emissivity3 | 0.95 |
Thermometer emissivity compensation | 0.9 to 1.0 |
Target diameter | 152.4 mm (6 in) |
Computer interface | RS-232 |
Power | 115 V AC (±10%), 6.3 A, |
50/60 Hz, 630 W | |
230 V AC (±10%), 3.15 A, | |
50/60 Hz, 630 W | |
Fuse(s) | 115 V AC 6.3 A, 250 V, slow blow |
230 V AC 3.15 A, 250 V, T | |
Size (H x W x D) | 356 x 241 x 216 mm |
(14 x 9.5 x 8.5 in) | |
Weight | 9.1 kg (20 lb) |
1. For 8 um to 14 um spectral band thermometers with emissivity set between 0.9 and 1.0 | |
2. The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature. | |
3. The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties. |
حفظ هذا المنتج في وقت لاحق