مطلوب تأكيد نهائي من الدعم. بمجرد تقديم طلبك، يرجى انتظار التأكيد النهائي من الشركة. ( 97144476031)
Fluke 718Ex Intrinsically Safe Pressure Calibrator
0.00 AED
متوفر في المتجر
تفاصيل المنتج
Brand:
Fluke
Range:
Via pressure module connector 29 pressure modules, 2.5 mbar to 700 bar
Resolution:
Per pressure module specs
Accuracy:
To 0.025% of full span, per pressure module specs
Over Pressure:
Over pressure per pressure module specs
Functions:
Zero, Min, Max, Hold, Damp
Power:
One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
Operating Temp.:
-10°C to 55°C
Storage Temp.:
-40°C to 60°C
Altitude:
3,000 m max
Size:
216 x 94 x 66 mm (with holster)
Weight:
Approx. 992 g (with holster)
Measure Accuracy Range:
0-24 mA
Display:
LCD, 5 digit pressure and current simultaneous
Shock & Vibration:
1 meter drop test, Random, 2 G, 5-500 Hz
Fluke 718Ex Intrinsically Safe Pressure Calibrator
The Fluke 718Ex Intrinsically Safe Pressure Calibrator is a cutting-edge instrument designed for use in potentially explosive environments. It is ATEX and IECEx certified, making it suitable for use in the oil, gas, chemical, and pharmaceutical industries where flammable gases, vapors, or dusts may be present. This calibrator is built to the highest safety and performance standards, ensuring accurate pressure measurements without compromising on safety.
Key Features
The Fluke 718Ex offers a range of features that make it an indispensable tool for professionals working in hazardous areas. Some of its key features include:
- ATEX and IECEx certifications, ensuring compliance with global safety standards.
- Pressure measurement range from -1 to 20 bar (-14.5 to 300 psi), covering a wide range of applications.
- Intrinsically safe design, preventing the possibility of ignition in hazardous atmospheres.
- Rugged construction, making it suitable for use in harsh industrial environments.
- Easy-to-use interface, allowing for quick and efficient pressure calibration.
Applications
This pressure calibrator is ideal for a variety of applications, including the calibration and maintenance of pressure transmitters, switches, and gauges. Its intrinsically safe design makes it the go-to choice for professionals working in environments where safety is of utmost importance. The Fluke 718Ex is widely used in oil and gas refineries, chemical plants, and pharmaceutical facilities.
Benefits
The Fluke 718Ex offers several benefits, including:
- Safety: Its intrinsically safe design provides peace of mind when working in hazardous areas.
- Accuracy: The calibrator ensures accurate pressure measurements, essential for maintaining process efficiency and safety.
- Efficiency: Its user-friendly interface and robust construction contribute to efficient and reliable performance in the field.
In conclusion, the Fluke 718Ex is a top-of-the-line pressure calibrator that meets the stringent safety requirements of the oil, gas, chemical, and pharmaceutical industries. Its ATEX and IECEx certifications, combined with its robust design and user-friendly interface, make it an essential tool for professionals working in hazardous environments. By investing in the Fluke 718Ex, companies can ensure the safety and efficiency of their pressure calibration processes.
Fluke 718Ex Intrinsically Safe Pressure Calibrator Specifications:
Pressure Measurement Accuracy | ||
Fluke 718Ex 30G | Range | -830 mbar to 2 bar (internal sensor) |
Over pressure: 3x FS | ||
Resolution | 0.0001 bar | |
Accuracy | 0.05% FS | |
Functions | Zero, Min, Max, Hold, Damp | |
Fluke 718Ex 100G | Range | -830 mbar to 2 bar (internal sensor) |
Over pressure: 2x FS | ||
Resolution | 0.001 bar | |
Accuracy | 0.05% FS | |
Functions | Zero, Min, Max, Hold, Damp | |
Fluke 718Ex 300G | Range | -830 mbar to 20 bar (internal sensor) |
Over pressure: 375 psi, 25 bar | ||
Resolution | 0.0001 bar | |
Accuracy | 0.05% FS | |
Functions | Zero, Min, Max, Hold, Damp | |
Fluke 718Ex series | Range | Via pressure module connector |
29 pressure modules, 2.5 mbar to 700 bar | ||
Over pressure per pressure module specs | ||
Resolution | Per pressure module specs | |
Accuracy | To 0.025% of full span, per pressure module specs | |
Functions | Zero, Min, Max, Hold, Damp | |
Source pressure, built in pump range | -820 mbar to full scale | |
For use with non-corrosive gasses. | ||
Supported Pressure Units psi, inH 2 O (4°C), inH 2 O (20°C), kPa, cmH 2 O (4°C), cmH 2 O (20°C), bar, mbar, kg/cm², mmHg, inHg | ||
Media compatibility per pressure module specs | ||
Technical Data | ||
Measure accuracy | Range | 0-24 mA |
Resolution | 0.001 mA | |
Accuracy | 0.02% rdg ±2 counts | |
Display | LCD, 5 digit pressure and current simultaneous | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 95% (10°C to 30°C) | |
75% (30°C to 40°C) | ||
45% (40°C to 50°C) | ||
35% (50°C to 55°C) | ||
Operating altitude | 3,000 m max | |
Safety Specifications | ||
Safety | ATEX II 1G Ex ia IIC T4 compliant | |
CSA Certification I.S. Class I | ||
Div 1 Groups A-D , T4 | ||
Mechanical and General Specifications | ||
Size (L x W x H) | 216 x 94 x 66 mm (with holster) | |
Weight | Approx. 992 g (with holster) | |
Warranty | Three years, one year for pump | |
Shock | 1 meter drop test | |
Vibration | Random, 2 G, 5-500 Hz | |
Battery type | One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V | |
Battery life | 4 to 20 hours, depending on functions used |