Fluke 729 Pro 4M Automatic Pressure Calibrator
0.00 AED
متوفر في المتجر
تفاصيل المنتج
Brand:
Fluke
Range:
-13 to 600 psi, -90 to 4000 kPa, -0.90 to 40 bar
Power:
Rechargeable lithium battery with charge indication (charged in the instrument or separately)
Operating Temp.:
-10 °C to 50 °C
Storage Temp.:
-20 °C to 60 °C
Altitude:
<3000 m
Size:
290 x 215 x100 mm, (4.3 x 4.4 x 9.4 in)
Weight:
4.9 kg, (10.8 lbs)
Loop Power Range:
24 V dc
Fluke 729 Pro 4M Automatic Pressure Calibrator
The Fluke 729 Pro 4M Automatic Pressure Calibrator is revolutionizing the field of pressure calibration with its advanced features and user-friendly design. This device is engineered to simplify the calibration process, save time, reduce errors, and improve accuracy, making it an essential tool for professionals in various industries.
The Fluke 729 Pro 4M is equipped with an internal electric pump that automatically generates and regulates pressure up to 7 MPa (70 bar, 1,000 psi). This feature allows users to set a target pressure, and the calibrator will automatically pump to the desired level, ensuring precise and efficient calibration.
Designed to streamline the calibration process, the Fluke 729 Pro 4M reduces the complexity and manual effort typically associated with pressure calibration. Its intuitive interface and automated functions enable technicians to perform calibrations quickly and accurately, minimizing downtime and increasing productivity.
Accuracy is paramount in pressure calibration, and the Fluke 729 Pro 4M delivers exceptional performance. By reducing human error and providing consistent results, this calibrator ensures reliable measurements that professionals can trust.
Whether working in the oil and gas industry, pharmaceuticals, manufacturing, or any other field requiring precise pressure calibration, the Fluke 729 Pro 4M is versatile enough to meet diverse needs. Its robust design and high-pressure capabilities make it suitable for a wide range of applications.
The handheld design of the Fluke 729 Pro 4M makes it easy to transport and use in various locations. Its rugged construction ensures durability, allowing it to withstand challenging environments and rigorous use.
The Fluke 729 Pro 4M is ideal for industrial maintenance tasks, where accurate pressure calibration is crucial for maintaining equipment performance and safety. It helps technicians ensure that machinery operates within specified parameters, preventing costly downtime and extending equipment life.
In manufacturing and production settings, maintaining precise pressure measurements is essential for quality control. The Fluke 729 Pro 4M provides the accuracy needed to verify and document pressure levels, ensuring that products meet industry standards and regulations.
For professionals offering calibration services, the Fluke 729 Pro 4M offers a reliable and efficient solution. Its automated features and high accuracy simplify the calibration process, allowing service providers to deliver high-quality results to their clients.
Fluke 729 Pro 4M Specifications
Key parameters | 729 Pro 7M | 729 Pro 4M |
Pressure control range | -13 to 1000 psi, -90 to 7000 kPa, | -13 to 600 psi, -90 to 4000 kPa, |
-0.90 to 70 bar | -0.90 to 40 bar | |
Pressure type | Gauge/absolute (Depends on the type of internal or external pressure module | |
Pressure accuracy and Control stability | 0.02% of FS, 0.005% of FS | |
Replaceable pressure measurement modules | Yes, 6 modules | Yes, 4 modules |
mA sourcing/measurement | Yes | |
Voltage measurement | Yes | |
Loop power | 24 V dc | |
Pressure switch testing | Yes | |
Pressure leakage testing | Yes | |
HART Communication | Yes, basic commands supported | |
Autostep / auto ramp | Yes (with customizable speed, mode and style) | |
Battery | Rechargeable lithium battery with charge indication (charged in the instrument or separately) | |
Language | English |
Electrical specification | |
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range. | |
Ranges | |
mA measure, source and simulate | 0 mA to 24 mA |
Volts dc measurement | 0 V dc to 30 V dc |
Resolution | |
mA dc source, simulate and measure | 1 μA |
Voltage dc measurement | 1 mV |
Accuracy | 0.01% FS ±2 LSD all ranges (at 23 °C ±5 °C) |
Stability | 20 ppm FS /°C (-10 °C to +18 °C and 28 °C to 50 °C) |
mA simulation working voltage | 12 V dc to 30 V dc |
Loop compliance voltage | 24 V dc @ 20 mA |
Temperature measurement , 100 Ω Pt(385) RTD | -50 °C to 150 °C |
Temperature resolution | 0.01 °C |
Temperature accuracy | ±0.1 °C ±0.25 °C combined uncertainty when using 720 RTD probe (optional accessory) |
Drive capability (mA source) | 1200 Ω (without HART resistor), 950 Ω (with internal HART resistor) |
Mechanical specification | |
Dimension (HxWxL) | 290 x 215 x100 mm, (4.3 x 4.4 x 9.4 in) |
Weight | 4.9 kg, (10.8 lbs) |
Environmental specification | |
Operating temperature | -10 °C to 50 °C |
Pressure control | 0 °C to 50 °C |
Battery charging | 0 °C to 40 °C |
Storage temperature | -20 °C to 60 °C |
Operating altitude | <3000 m |
Storage altitude | <13000 m |
Operating humidity | Non-condensing (<10°C) |
≤90 % RH (10 °C to 30 °C) | |
≤75 % RH (30 °C to 40 °C) | |
≤45 % RH (40 °C to 50 °C) |