Meriam Z5150-MERX HART Compliant Communicator
0.00 AED
متوفر في المتجر
تفاصيل المنتج
Brand:
Meriam
V DC:
15 V DC
V AC (True RMS):
100-240 V AC
mA DC:
1600 mA
Frequency :
50/60 Hz
DC Current Output:
1600mA
Operating Temperature:
+14°F (-10°C) to +122°F (+50°C)
Storage Temperature:
-4°F (-20°C) to +131°F (+55°C)
Shock:
Tested to survive a 1m drop onto concrete
Dimensions:
11.9×5.6×1.9 inch [303×142×48 mm]
Weight:
Approx. 2 lbs
Meriam Z5150-MERX
The Meriam Z5150-MERX HART Compliant Communicator is a specialized handheld device designed for the configuration, calibration, and maintenance of HART (Highway Addressable Remote Transducer) devices. This communicator is essential in various industrial applications, enabling users to interact effectively with HART-enabled instruments.
Key Features
- HART Communication: The Z5150-MERX supports both standard and advanced HART communication protocols, allowing for comprehensive interaction with a wide range of HART devices. This includes the ability to read and write device parameters, perform diagnostics, and configure devices.
- User-Friendly Interface: The device is equipped with an intuitive graphical user interface that simplifies navigation through menus and options. The display is designed for clarity, even in challenging lighting conditions.
- Device Description (DD) Files: The communicator can read manufacturers' DD files in their native format without requiring translations. This feature ensures accurate representation of device parameters and diagnostics.
- Ergonomic Design: The Z5150-MERX is designed for ease of use in field conditions, featuring a lightweight and portable design that enhances user comfort during prolonged use.
- Multi-Language Support: Integrated support for multiple languages makes the communicator accessible to a diverse range of users across different regions.
Applications
The Meriam Z5150-MERX is utilized across various sectors, including:
- Oil and Gas: For monitoring and managing field devices in exploration and production.
- Chemical Processing: To ensure accurate measurements and control of process parameters.
- Water Treatment: For maintaining compliance with regulatory standards through effective monitoring of water quality instruments.
In summary, the Meriam Z5150-MERX HART Compliant Communicator is a powerful tool that enhances the efficiency of device management in industrial settings. Its robust features, user-friendly design, and compatibility with various HART devices make it an invaluable asset for technicians and engineers alike.
Meriam Z5150-MERX Specifications
Supported Applications | Endress + Hauser FieldCare for HART, PROFIBUS PA and FF devices | |
Pactware for HART, PROFIBUS PA and FF devices | ||
ProComSol DevCom for HART and FF devices | ||
AMS Device Manager for HART devices | ||
User Interface | Controls and Status LEDs | Power on/off button, Bluetooth pairing button |
FIELDBUS (Fieldbus mode), HART (HART mode), Bluetooth (Pairing/Bluetooth active), Low battery, Power on | ||
Interfaces and Connectors | USB | Speed: USB 2.0 Full Speed, Connector: USB Type C |
Electrical: Non intrinsically safe. Do not use inside hazardous areas. 5 V, 100 mA. Um = 253 V | ||
Bluetooth | Dual Mode (BT Classic and BLE), 2.4 - 2.478 GHz, Output Power: +8 dBm (maximum) | |
Fieldbus | Connection: 4 mm banana type jacks (red/black), polarity has to be observed | |
Physical Layer: according to IEC 61158-2, Type 1: 31.25 Kbit/s, voltage mode | ||
Nominal input current (Fieldbus): | ||
10 mA in Bluetooth and regular USB mode | ||
18 mA (with fieldbus voltage > 9,5V) for increased battery life time in USB mode (controlled by application) | ||
Fieldbus Terminator: No built-in fieldbus terminator | ||
HART | Connection: 4 mm banana type jacks (red/black) | |
Physical Layer: HART FSK compliant modem | ||
Operation in Hazardous Areas | Intrinsic Safety | EX ia IIB, Ui = 30 V or FISCO field device |
Parameters | Isolation: 1500 VDC between USB and Fieldbus, 1500 VDC between USB and HART | |
IECEx | Ex ib [ia Gb] IIB (HW version 1.00), IIC (HW version 1.01) T4 Gb; Ex ib [ia Da] IIIC T100°C Db | |
ATEX | II 2G Ex ib [ia Ga] IIB (HW version 1.00), IIC (HW version 1.01) T4 Gb; II 2D Ex ib [ia Da] IIIC T100°C Db | |
Physical Properties | Dimensions (L x W x D) | 175 mm x 74 mm x 32 mm |
Weight | 330 g (incl. Batteries) | |
Power Supply | Battery: 3 * Alkaline, IEC-LR6, nominal voltage 1,5 V | |
For use in hazardous area: Energizer E91 or Duracell Procell MN1500. | ||
With batteries of other types or manufacturers certification is void. | ||
Fieldbus interface (Medium Attachment Unit) powered by fieldbus. | ||
Operating Temperature | -20°C .. +50°C | |
Storage | Store batteries in a dry place at normal room temperature. | |
Relative Humidity | < 95% rH non condensing | |
Protection Class | IP 54 (if USB port covered with cap) | |
Certifications | Ex | ATEX, IECEx, FM, PCEC, KC, EAC, PESO |
EMC/Radio | CE, FCC, SRRC, ETA, MIC, KC, EAC, TRA | |
ROHS | UAE |