final confirmation from support is required. Once your order is placed, please await final confirmation from the company. (+97144476031)
Eurotron PLB 150 Portable Liquid Bath
Eurotron PLB 150 Portable Liquid Bath
The PLB 150 portable liquid bath features a spacious calibration volume of 60mm x 170mm deep, making it an excellent choice for use as a portable liquid bath. Stirred liquid baths are suitable for various types and shapes of temperature sensors, offering smaller calibration uncertainties (stability, uniformity, and accuracy) compared to dry block calibrators.
The Eurotron PLB 150 excels in providing precise temperature control, which is critical for accurate calibration. With a temperature range of -35°C to 165°C, it covers a wide spectrum suitable for various applications. The stability and uniformity of the temperature within the bath are impressive, ensuring consistent and reliable results every time. This level of performance is essential for maintaining the accuracy of temperature-sensitive instruments.
Eurotron PLB 150 Key Features
- Temperature range:-18 to 140 ºC
- Large calibration volume: Ø 60 x 170 mm
- Accuracy better than ±0.08 C using external reference sensor
- High stability: ± 0.02 ºC
- Best in class radial uniformity: ± 0.02 ºC
- Inputs for reference sensor and sensor under test
- Fully programmable ramp
- Automatic switch test function
- Use as stirred liquid bath, ice point, dry block, black body target and surface sensors temperature calibrator
- RS232 and calibration software as standard
Eurotron PLB 150 Specifications
Temperature Range | |
@ 20ºC | -18 C to 140 C |
@ 0ºC | -38 to 140°C |
Stability | |
As Liquid Bath | ± 0.01 °C |
As Dry block | ± 0.01 °C |
Uniformity as Liquid Bath | |
Axial | ± 0.02 °C @ -10 °C ± 0.02 °C@ 0°C ± 0.01 °C @ 120 °C |
Radial | ± 0.01 °C @ -10 °C ± 0.01 °C@ 0°C ± 0.02 °C @ 120 °C |
Accuracy | |
with Internal Sensor | ± 0.15 °C |
with External Sensor SRS (*) | ± 0.08 °C ( TC version only) |
Display | |
Resolution | user-selectable 0.1 , 0.01 C |
Units | user-selectable C, F,K |
Calibration Volume | |
As Liquid Bath | 54 x 150 mm |
As dry block | 60 x 170 mm |
Heating time | ambient to 120°C: 30 min ( include time to stability) |
Cooling time | ambient to -10°C : 30 min (include time to stability) |
Thermocouple Input (TC version) | |
Type | K,N,R,S,J,E |
Range | 0 to 1300 °C |
Accuracy | ± 1°C Include CJC error |
Resolution | user-selectable 0.1 , 0.01 °C |
RTD’S input ( TC version only) | |
Type | Pt 100 (3/4 wires) |
Range | -100 C to 700 °C |
Accuracy | ± 0.3 °C |
Resolution | user-selectable 0.1 , 0.01 °C |
General | |
Computer interface | RS 232 as standard ( UBS adapter supplied as option) and EIUK software included |
Switch Test | Yes |
Ramp | Yes fully programmable |
Weight | 8 Kg |
Dimensions | 160x340x330 mm |
Power Requirement | 115 o 230 V – 50/60 Hz |
Power | 300 VA |
Notes | * Require SRS sensor and special UKAS matching calibration. Long term drift not included |