final confirmation from support is required. Once your order is placed, please await final confirmation from the company. (+97144476031)
Fluke 3000 FC/1AC2 Advanced Combo Kit
0.00 AED
In stock
Product Details
Brand:
Fluke
AC Voltage Range:
1000 V
DC Voltage Range:
1000 V
AC Current Range:
400.0 mA
DC Current Range:
400.0 mA
AC Voltage Overload Protection:
1100 V RMS
DC Voltage Overload Protection:
1100 V RMS
Resistance Range:
50.00 MΩ
Capacitance Range:
9999 μF
Frequency Range :
99.99 kHz
Diode test:
2.000 V
Power:
Three AA Alkaline batteries, NEDA 15A IEC LR6
Dimension:
4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight:
340 g (12 oz)
Continuity buzzer:
600 Ω
Fluke 3000 FC/1AC2 Combo Kit
The Fluke 3000 FC/1AC2 Combo Kit epitomizes innovation and efficiency in the realm of electrical testing and measurement.
Wireless Connectivity: One of the standout features of the Fluke 3000 FC/1AC2 Combo Kit is its wireless connectivity capabilities. Utilizing Fluke Connect®, technicians can remotely monitor and log data from the multimeter using their smartphones or tablets. This wireless functionality enhances flexibility and convenience, particularly in challenging or hazardous environments.
True RMS Accuracy: Equipped with True RMS technology, the Fluke 3000 FC multimeter delivers accurate measurements even in non-linear electrical systems. This ensures reliability in diagnosing electrical issues across a wide range of applications, from industrial settings to residential installations.
Integrated Voltage Detector: The inclusion of the Fluke 1AC II non-contact voltage detector in the combo kit adds an extra layer of safety and efficiency to electrical work. With its ability to quickly identify the presence of voltage without physical contact, technicians can assess circuits swiftly, reducing the risk of electrical hazards.
User-Friendly Design: Designed with the end-user in mind, the Fluke 3000 FC/1AC2 Combo Kit boasts a user-friendly interface and ergonomic construction. The multimeter features a large digit display with an analog bargraph, ensuring readability even in dimly lit conditions. Additionally, the display backlight enhances visibility, further facilitating ease of use.
Versatile Application: Whether in industrial maintenance, HVAC troubleshooting, or residential electrical inspections, the Fluke 3000 FC/1AC2 Combo Kit offers versatile functionality to meet diverse needs. Its comprehensive set of measurement capabilities, combined with wireless connectivity and safety features, makes it a valuable asset for electricians, technicians, and maintenance professionals alike.
Fluke 3000 FC/1AC2 Combo Kit Specifications
AC Voltage | ||
Range¹ / resolution | 600.0 mV / 0.1 mV | |
6.000 V / 0.001 V | ||
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
1000 V / 1 V | ||
Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 |
500 Hz to 1 kHz | 2.0% + 3 | |
1. AC voltage ranges are specified from 1% of range to 100% of range. | ||
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. | ||
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. | ||
4. Do not exceed 107 V-Hz. | ||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||
mV | Range / resolution | 600.0 mV / 0.1 mV |
Accuracy | 0.09% + 2 | |
V | Range / resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
1000 V / 1 V | ||
Accuracy | 0.09% + 2 | |
0.15% + 2 | ||
))) | Range / resolution | 600 Ω / 1 Ω |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | Range / resolution | 600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ | ||
60.00 kΩ / 0.01 kΩ | ||
60.00 kΩ / 0.1 kΩ | ||
600.0 kΩ / 0.001 MΩ | ||
50.00 MΩ / 0.01 MΩ | ||
Accuracy | 0.5% + 2 | |
0.5% + 1 | ||
1.5% + 3 | ||
Diode test | Range / resolution | 2.000 V / 0.001 V |
Accuracy | 1% + 2 | |
µF | Range / resolution | 1000 nF / 1 nF |
10.00 μF / 0.01 μF | ||
100.0 μF / 0.1 μF | ||
9999 μF1 / 1 μF | ||
Accuracy | 1.2% + 2 | |
10% typical | ||
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | ||
AC and DC Current | ||
mA AC | Range1 / resolution | 60.00 mA / 0.01 mA |
(45 Hz to 1 kHz) | 400.0 mA3 / 0.1 mA | |
Accuracy | 1.5% + 3 | |
mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA |
400.0 mA3 / 0.1 mA | ||
Accuracy | 0.5% + 3 | |
1. All AC current ranges are specified from 5% of range to 100% of range. | ||
2. Input burden voltage (typical): 400 mA input 2 mV/mA. | ||
3. 400.0 mA accuracy specified up to 600 mA overload. | ||
Frequency | ||
Range / resolution | 99.99 Hz / 0.01 Hz | |
999.9 Hz / 0.1 Hz | ||
9.999 kHz / 0.001 kHz | ||
99.99 kHz / 0.01 kHz | ||
Accuracy1 | 0.1% + 1 | |
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||
Input Characteristics | ||
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio | > 120 dB at DC, 50 Hz or 60 Hz | |
(1 kΩ unbalance) | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio | > 60 dB, DC to 60 Hz | |
(1 kΩ unbalance) | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio | > 120 dB at DC, 50 Hz or 60 Hz | |
(1 kΩ unbalance) | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | ||
Overload protection | 1100 V RMS | |
Input impedance (nominal) | < 2.7 V DC | |
Full scale voltage to 6 MΩ | < 0.7 V DC | |
Full scale voltage 50 MΩ | < 0.9 V DC | |
Typical short circuit current | < 350 mA | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | < 2.7 V DC | |
Full scale voltage to 6 MΩ | 2.000 V DC | |
Full scale voltage 50 MΩ | ||
Typical short circuit current | < 1.1 mA | |
mA Function | ||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | |
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | |
MIN/MAX Recording Accuracy | ||
DC functions | ± 12 counts for changes > 350 mS in duration. | |
AC functions | ± 40 counts for changes > 900 mS in duration. | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | |
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |
Display (LCD) | Update rate | 4/sec |
Volts, amps, ohms | 6000 counts | |
Frequency | 10,000 counts | |
Capacitance | 1,000 counts | |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | |
Battery life | 250 hours minimum | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20m |
Obstructed, sheetrock wall | Up to 6.5m | |
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | |
Temperature | Operating | -10°C to 50°C |
Storage | -40°C to 60°C | |
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) | |
Relative humidity | 0% to 90% (0°C to 35°C) | |
0% to 75% (35°C to 40°C) | ||
0% to 45% (40°C to 50°C) | ||
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
Electromagnetic compatibility | EN 61326–1:2006, EN 61326–2–2:2006 | |
EMI, RFI, EMC, RF | ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 | |
V1.8.1:2008 | ||
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 | ||
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE | ||
Safety compliance | ANSI / ISA 61010–1 / (82.02.01): 3rd edition | |
CAN / CSA-C22.2 No 61010-1-12: 3rd edition | ||
UL 61010–1: 3rd edition | ||
IEC / EN 61010–1:2010 | ||
Certifications | CSA, FCC, CE | |
Ingress Protection (IP) rating | IP54 | |
Pollution Degree | 2 | |
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | |
Weight | 340 g (12 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |
Save this product for later
Fluke 3000 FC/1AC2 Advanced Combo Kit
Display prices in:
AED