Fluke 376 FC True-RMS Clamp Meter with iFlex
Fluke 376fc clamp meter with iflex
The Fluke 376 FC True-rms Clamp Meter with iFlex stands as the ultimate diagnostic solution for industrial and commercial electricians. It falls within the Fluke Connect lineup of wireless testing instruments, allowing users to securely log, track, and observe measurements via Bluetooth connection. This innovation ensures a safe distance from arc flash hazards while still gaining real-time insights into measurements.
Enhanced Accuracy in Electrical Diagnostics: The clamp meter 376 fluke Advanced Filtering and Inrush Measurement Capabilities
The Fluke 376 FC true rms clamp meter utilizes a built-in low-pass filter to ensure precise measurements of non-linear signals, including adjustable speed drives, electronic ballasts, and other types of non-linear loads. Additionally, the clamp incorporates exclusive inrush measurement technology to effectively eliminate noise and precisely capture the motor's starting current, mirroring the circuit protection's perception.
Here at UAZON, our dedication revolves around delivering outstanding customer service. Our team of experts is fully prepared to guide you in choosing the optimal measuring instrument tailored to your specific application. To get information about the fluke 376 fc price contact our experts.
Fluke 376 Clamp Meter Features
- Voltage to 1000 V AC or DC
- Resistance to 60 kΩ with continuity detection
- Min, max, average, and inrush recording to capture variations automatically
- 500 mV DC measurement range to interface with other accessories
- 1000 μF capacitance measurement
- Work safely and conveniently
- The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.
Fluke 376 FC Specifications
General Specifications |
||||||
|
||||||
AC Current via Jaw |
||||||
Range |
999.9 A |
|||||
Resolution |
0.1 A |
|||||
Accuracy |
2% ±5 digits (10 Hz to 100 Hz) |
|||||
2.5% ±5 digits (100-500 Hz) |
||||||
Crest Factor (50 Hz/60 Hz) |
3 @ 500 A |
|||||
2.5 @ 600 A |
||||||
Add 2% for C.F. >2 |
||||||
AC Current via Flexible Current Probe |
||||||
Range |
2500 A |
|||||
Resolution |
0.1 A (≤ 600 A) |
|||||
1 A (≤ 2500 A) |
||||||
Accuracy |
3% ±5 digits (5 – 500 Hz) |
|||||
Crest Factor (50/60Hz) |
3.0 at 1100 A |
|||||
2.5 at 1400 A |
||||||
1.42 at 2500 A |
||||||
Add 2% for C.F. > 2 |
||||||
i2500-10 Flex |
i2500-18 Flex |
i2500-36 Flex |
||||
A |
||||||
Distance from Optimum |
0.5 in (12.7 mm) |
1.4 in (35.6 mm) |
4.8 in (122.2 mm) |
|||
Error |
±0.5 % |
±0.5 % |
±0.5 % |
|||
B |
||||||
Distance from Optimum |
0.8 in (20.3 mm) |
2.0 in (50.8 mm) |
5.3 in (133.6 mm) |
|||
Error |
±1.0 % |
±1.0 % |
±1.0 % |
|||
C |
||||||
Distance from Optimum |
1.4 in (35.6 mm) |
2.5 in (63.5 mm) |
5.8 in (147.6 mm) |
|||
Error |
±2.0 % |
±2.0 % |
±2.0 % |
|||
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. |
||||||
DC Current |
||||||
Range |
999.9 A |
|||||
Resolution |
0.1 A |
|||||
Accuracy |
2% ±5 digits |
|||||
AC Voltage |
||||||
Range |
1000 V |
|||||
Resolution |
0.1 V (≤600.0 V) |
|||||
1 V (≤1000 V) |
||||||
Accuracy |
1% ±5 digits (20 Hz to 500 Hz) |
|||||
DC Voltage |
||||||
Range |
1000 V |
|||||
Resolution |
0.1 V (≤600.0 V) |
|||||
1 V (≤1000 V) |
||||||
Accuracy |
1% ±5 digits |
|||||
mV dc |
||||||
Range |
500.0 mV |
|||||
Resolution |
0.1 mV |
|||||
Accuracy |
1% ±5 digits |
|||||
Frequency via Jaw |
||||||
Range |
5.0 Hz to 500.0 Hz |
|||||
Resolution |
0.1 Hz |
|||||
Accuracy |
0.5% ±5 digits |
|||||
Trigger level |
5 Hz to 10 Hz, ≥10 A |
|||||
10 Hz to 100 Hz, ≥5 A |
||||||
100 Hz to 500 Hz, ≥10 A |
||||||
Frequency via Flexible Current Probe |
||||||
Range |
5.0 Hz to 500.0 Hz |
|||||
Resolution |
0.1 Hz |
|||||
Accuracy |
0.5% ±5 digits |
|||||
Trigger level |
5 Hz to 20 Hz, ≥25 A |
|||||
20 Hz to 100 Hz, ≥20 A |
||||||
100 Hz to 500 Hz, ≥25 A |
||||||
Resistance |
||||||
Range |
60 kΩ |
|||||
Resolution |
0.1 Ω (≤600 Ω) |
|||||
1 Ω (≤6000 Ω) |
||||||
10 Ω (≤60 kΩ) |
||||||
Accuracy |
1% ±5 digits |
|||||
Capacitance |
||||||
Range |
1000 μF |
|||||
Resolution |
0.1 μF (≤ 100 μF) |
|||||
1 μ F (≤ 1000 μF) |
||||||
Accuracy |
1% ±4 digits |
|||||
Mechanical Specifications |
||||||
Maximum voltage between any terminal and earth ground |
1000 V |
|||||
Batteries |
2 AA, NEDA 15A, IEC LR6 |
|||||
Operating temperature |
-10 °C to +50 °C |
|||||
Storage temperature |
-40 °C to +60 °C |
|||||
Operating humidity - |
≤90% RH (at 10 °C to 30 °C) |
|||||
≤75% RH (at 30 °C to 40 °C) |
||||||
≤45% RH (at 40 °C to 50 °C) |
||||||
Operating altitude |
2000 m |
|||||
Storage altitude |
12,000 m |
|||||
Size (L x W x H) |
249 x 85 x 45 mm |
|||||
Weight |
395 g |
|||||
Jaw opening |
34 mm |
|||||
Flexible current probe diameter |
7.5 mm |
|||||
Flexible current probe cable length |
1.8 m |
|||||
Safety |
IEC 61010-1, Pollution Degree 2 |
|||||
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V |
||||||
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V |
||||||
IP rating |
IEC 60529: IP30, non-operating |
|||||
Radio Frequency Certification FCC ID |
T68-FBLE IC:6627A-FBLE |