final confirmation from support is required. Once your order is placed, please await final confirmation from the company. (+97144476031)
Fluke Norma 6003+ Portable Power Analyzer
0.00 AED
In stock
Product Details
Brand:
Fluke
Number of Inputs:
3 Voltage + 3 Current + 1 Motor
Measurement Range:
10 V, 100 V, 1000 V
Bandwidth:
1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
Frequency:
100 kHz
Sampling Rate:
200ks/s
Dimensions:
298mm x 215m x 96mm
Weight:
3.5 kg (7.7 lbs)
Memory :
32GB
Operating Temperature:
-10 °C to +50 °C
Storage Temperature:
-30 °C to +60 °C
Interfaces:
USB/RS485
Display:
5.7 inch, TFT LCD, 640x480
Power :
BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Fluke Norma 6003+ Portable Power Analyzer
The Fluke 6003+ Portable Power Analyzer is more than just a measurement tool; it is a comprehensive solution for power analysis. Here are some key reasons why it is the preferred choice for professionals in the field:
- Comprehensive Power Analysis: The Fluke 6003+ measures a wide range of electrical parameters, including voltage, current, active power, reactive power, apparent power, power factor, and harmonics. This makes it an all-in-one tool for thorough power analysis.
- High Accuracy: With state-of-the-art technology, the Fluke 6003+ delivers precise measurements, ensuring that all readings are accurate and reliable. This high level of accuracy is essential for diagnosing power quality issues and optimizing electrical systems.
- Portability and Convenience: Despite its advanced capabilities, the Fluke 6003+ is designed to be portable and easy to use. Its compact size and user-friendly interface allow technicians to perform complex measurements on-site with ease.
- Speed and Torque Measurements: Unique to the Fluke 6003+ is its ability to measure speed and torque, providing additional data points for comprehensive power analysis. This feature is particularly valuable in applications involving motors and other rotational equipment.
Applications of the Fluke 6003+
The versatility of the Fluke 6003+ makes it suitable for a wide range of applications, including:
- Industrial Automation: Ensuring that industrial machines and systems operate efficiently and within specified power parameters.
- Energy Management: Monitoring and optimizing energy consumption in commercial and industrial facilities to reduce costs and improve sustainability.
- Electrical Maintenance: Performing routine checks and troubleshooting electrical systems to prevent downtime and ensure continuous operation.
- Research and Development: Providing detailed power measurements for the development and testing of new electrical products and systems.
Key Features of the Fluke 6003+
- Multi-Channel Measurement: The Fluke 6003+ offers three channels, allowing simultaneous measurement of multiple power parameters. This multi-channel capability enhances efficiency and provides a more comprehensive view of the power system.
- Data Logging and Analysis: With extensive data logging capabilities, the Fluke 6003+ enables long-term monitoring and analysis of power systems. This helps in identifying trends and diagnosing intermittent issues that might not be apparent in short-term measurements.
- User-Friendly Interface: The intuitive interface of the Fluke 6003+ simplifies the setup and measurement process, making it accessible to both experienced professionals and newcomers to power analysis.
- Robust Design: Built to withstand the harsh conditions of industrial environments, the Fluke 6003+ is durable and reliable, ensuring consistent performance even in challenging settings.
Benefits of Using the Fluke 6003+
- Enhanced Decision Making: Accurate and comprehensive power measurements enable better decision-making in system design, maintenance, and troubleshooting.
- Cost Savings: By identifying inefficiencies and optimizing power usage, the Fluke 6003+ can help reduce energy costs and extend the lifespan of electrical equipment.
- Improved Safety: Accurate power analysis helps in identifying potential safety hazards, ensuring that electrical systems operate within safe parameters.
Fluke Norma 6003+ Portable Power Analyzer Specifications
Inputs | Norma 6003 | 3 Voltage + 3 Current |
Norma 6003+ | 3 Voltage + 3 Current + 1 Motor | |
Norma 6004 | 4 Voltage + 4 Current | |
Norma 6004+ | 4 Voltage + 4 Current + 1 Motor | |
Sample rate | 200ks/s | |
Measurement update rate | 100ms, 200ms, 500ms, 1s | |
Dimensions (H * W * L) | 298mm x 215m x 96mm | |
Weight | 3.5 kg (7.7 lbs) | |
Display | 5.7 inch, TFT LCD, 640x480 | |
Operating temperature | -10 °C to +50 °C | |
Storage temperature | -30 °C to +60 °C | |
Operating humidity | Non-condensing (< 10 °C ) | |
≤ 90 % RH (at 10 °C to 30 °C) | ||
≤ 75 % RH (at 30 °C to 40 °C) | ||
≤ 45 % RH (at 40 °C to 50 °C) | ||
Operating altitude | 2000m | |
Storage altitude | 12000m | |
Ingress protection | IP 50 (Terminals mated) according to IEC 60529: | |
Battery | BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3 | |
Operating time: 10 Hours (on battery) | ||
Safety | IEC 61010-1: Pollution Degree 2 | |
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V | ||
EMC | IEC 61326-1: Industrial | |
IEC 61326-2-2 | ||
Warranty | 1 Year | |
Communication Interface | USB/RS485 | |
Dual Analyzer Synchronization Mode | Able to extend to 6, 7 or 8 channels (using multiple instruments) | |
PC Software | Fluke Power Analyzer software | |
Storage Capacity | 32GB | |
Data trend storage rate | As per display rate | |
Main Function | Meter, Scope, Harmonic, Phasor, Trend | |
Measuring Parameters | RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function |
Electrical Specifications | |
Voltage | |
Range | 10 V, 100 V, 1000 V |
Crest Factor | CF ≤ 2 |
Maximum Voltage | 10 % overload |
Input Impedance | 2M Ω/10pF (Typical) |
Temperature Coefficient | 0.05 * (Spec)/k |
Bandwidth | 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz |
CMRR | 120 dB @ 50/60 Hz |
Accuracy (% reading + % range) | |||
Range | 1000 V | 100 V | 10 V |
DC | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 |
AC (10Hz to 1kHz) | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 |
AC (10kHz) | 5 + 0.5 | 5 + 0.5 | 5 + 0.5 |
Current | |||
Crest Factor | CF ≤ 2 | ||
Temperature Coefficient | 0.05 x (Spec)/k | ||
Overload capacity | 10 % overload | ||
CMRR | 120 dB @ 50/60 Hz | ||
Shunt (current input) | |||
Measuring Range | 0.1 A, 1 A, 10 A | ||
Input Impedance | 0.025 Ω (Typical) | ||
Bandwidth | 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz | ||
BNC (voltage input) | |||
Range | 0.1 V, 1 V, 10 V | ||
Input Impedance | 100k Ω/100pF (Typical) | ||
Bandwidth | 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz |
Accuracy (% reading + % range) | ||||||
Range | 10 A | 1 A | 0.1 A | 10 V | 1 V | 0.1 V |
DC | 0.1 + 0.2 | 0.1 + 0.5 | 0.1+2 | 0.1+0.1 | 0.1+0.2 | 0.1+1 |
AC (10Hz to 1kHz) | 0.1+0.1 | 0.1+0.2 | 0.1+1 | 0.1+0.1 | 0.1+0.1 | 0.1+0.5 |
AC (10kHz) | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 |
Motor Module (Torque and Speed) | ||||||
Voltage Range | ± 10 V dc, 10 % overload | |||||
Voltage Channels | 2 | |||||
Input Impedance | 1.1M Ω (Typical) | |||||
Accuracy at dc | 0.1 % range + 0.1 % reading | |||||
Pulse Channels | 3 | |||||
Pulse Logic High Threshold | 2 V (Typical) | |||||
Pulse Logic Low Threshold | 0.8 V (Typical) | |||||
Maximum Pulse Frequency | 100 kHz | |||||
Motor Module (Torque and Speed) | ||||||
Frequency Accuracy | 0.05 % range + 0.05 % reading | |||||
Harmonics | 100 (50Hz/60Hz) | |||||
Calculation method | FFT/Interpolation |
Save this product for later
Fluke Norma 6003+ Portable Power Analyzer
Display prices in:
AED