final confirmation from support is required. Once your order is placed, please await final confirmation from the company. (+97144476031)

Met One GAS-1030 Carbon Monoxide Analyzer

0.00 AED
In stock
Product Details

Met One GAS-1030 Carbon Monoxide Analyzer

The Met One GAS-1030 is a highly precise and reliable ozone (O3) analyzer designed for ambient air monitoring. Utilizing proven non-dispersive ultraviolet (UV) absorption technology, it measures ozone concentrations ranging from 0 to 20 ppm with exceptional accuracy. The device supports various concentration units, including mg/m3, μg/m3, ng/m3, ppm, ppb, and ppt.

Key specifications of the GAS-1030 include a noise level of less than 0.25 ppb and a lower detectable limit of less than 0.5 ppb. The linearity is maintained at less than 1% of the full scale, and the precision is 0.5 ppb or 0.2% of the reading, whichever is greater. Zero drift is minimal, with less than 0.3 ppb over 24 hours and the same over seven days. The span drift is less than 0.5% of the reading or 0.3 ppb over seven days.

Met One GAS-1030 Key Features

  • Reliable performance backed up by a two-year warranty
  • Minimize time spent on site performing maintenance through superior remote instrument control, diagnostic viewing, and calibration
  • Comprehensive data logging and remote viewing of over 200 operational parameters.
  • Versatile interfacing through RS232, USB, analog and digital I/O, TCP/IP, and optional Bluetooth.
  • Easy setup through an intuitive menu system, advanced GUI, and a large alphanumeric keypad with tactile keys.
  • Instant status indication via illuminated instrument status light buttons on the front panel.

Met One GAS-1030 Specifications

Parameter Specification
Range 0 to 200 ppm (auto-ranging)
Concentration Units mg/m3, μg/m3, ng/m3, ppm, ppb, or ppt
Noise < 0.02 ppm or 0.2% of concentration reading, whichever is greater
Lower Detectable Limit < 0.04 ppm
Linearity < 1% of full scale (0 - 50 ppm)
Precision 0.1 ppm or 0.1% of reading, whichever is greater
Zero Drift 24 hours: < 0.1 ppm<br>7 days: < 0.1 ppm
Span Drift 7 days: < 0.5% of reading or 0.1 ppm, whichever is greater
Response Time 60 seconds to 95%
STP Reference 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample Flow Rate 1000 cc/min
Temperature Range 0 to 40 °C
Power 100 - 240 VAC, 50 - 60 Hz (auto-ranging)
Power Consumption 260 VA (max at start-up)<br>150 VA (nominal)
Dimensions 429 x 175 x 638 mm
Rack Spacing 3.5 RU
Weight 17.8 kg
Save this product for later
Share this product with your friends
Met One GAS-1030 Carbon Monoxide Analyzer