​Fluke 1623-2-KIT Advanced Geo Earth Ground Tester Kit

0.00 AED
In stock
Product Details
UPC: 95969666862
Brand: Fluke
Earth Resistance Range: 0.020 Ω to 19.99 kΩ
AC Earth Voltage Range: 48 V ac
DC Voltage Range: 24 V
Resistance Range: 0.020 Ω to 19.99 kΩ
Overload Protection: Maximum Overload: 250 V rms (pertains to misuse)
Dimension: 9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)

Fluke 1623-2 Kit Advanced Geo Earth Ground Tester

The Fluke 1623 2 KIT Advanced Geo Earth Ground Tester Kit is a state-of-the-art tool designed to facilitate fast, accurate, and easy measurements of earth ground. This comprehensive testing kit is equipped with advanced features to meet the diverse needs of professionals across various industries.
The Fluke 1623-2-KIT is a compact, field-rugged instrument that performs all four types of earth ground measurement, including 3- and 4-Pole Fall-of-Potential, 4-Pole Soil Resistivity testing, selective testing, and stakeless testing. This versatility makes it an ideal solution for professionals who need to conduct comprehensive earth ground testing in a variety of settings.
The kit features Automatic Frequency Control (AFC) to minimize the impact of interference, along with R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth, ensuring precise and reliable measurements. Additionally, the kit offers adjustable limits for expedited testing, enhancing efficiency during the testing process.

Fluke 1623 2 KIT:

Robust Design for Challenging Environments, IP56 Rated for Outdoor Use, and Enhanced Data Management Features

The Fluke 1623-2-KIT is designed to withstand challenging environmental conditions, with an IP56 rating for outdoor use and a rugged carrying case. It also comes with a USB port for seamless data storage and transfer, allowing users to manage and analyze test data with ease.

In comparison to the Fluke 1625-2 GEO Earth Ground Tester, the Fluke 1623-2-KIT is a basic version of the advanced model. However, it still offers a comprehensive set of features and functionalities to meet the diverse needs of professionals in the field. The Fluke 1623-2-KIT is a high accuracy earth ground tester with built-in memory, four different testing methods, and several other useful features.
In conclusion, the Fluke 1623-2-KIT Advanced Geo Earth Ground Tester Kit is a state-of-the-art tool that offers a comprehensive set of features and functionalities to meet the diverse needs of professionals in the field. Its advanced capabilities, versatile testing options, and focus on convenience and efficiency make it an invaluable asset for accurate and efficient earth ground measurements.

Fluke 1623-2-KIT Advanced Geo Earth Ground Tester Kit Specifications:

Temperature Range
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Temperature Coefficient ±0.1% of reading/°C <18°C >28°C
Intrinsic Error Refers to the reference temperature range and is guaranteed for one year
Operating Error Refers to the operating temperature range and is guaranteed for one year
Climatic Class C1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RH
Protective Type IP56 for case, IP40 for battery door according to EN60529
Safety Protection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree two
EMC (Emission Immunity) IEC61326-1: Portable
Quality System Developed, designed, and manufactured according to DIN ISO 9001
External Voltage V external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher values
V Ext Rejection >120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring Time Typical six seconds
Maximum Overload 250 V rms (pertains to misuse)
Auxiliary Power 6 x 1.5 V Alkaline (type AA LR6)
Battery Life Span Typical >3000 measurements
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position R A 3-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (R S ) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (R H ) Maximum 100 kΩ
Additional Error from R H and R S R H [kΩ]R S [kΩ]/R A [Ω]0.2%
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position R A 4-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (R S + R ES ) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (R H ) Maximum 100 kΩ
Additional Error from R H and R S R H [kΩ]R S [kΩ]/R A [Ω]0.2%
Monitoring of R S and R H with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position R A 3-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (R S ) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (R H ) Maximum 100 kΩ
Monitoring of R S and R H with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position R A 4-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (R S ) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (R H ) Maximum 100 kΩ
Monitoring of R S and R H with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch Position R A 4-pole 2 clamps
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring Voltage Vm = 48 V ac
Measure Frequency 128 Hz
Noise Current (I EXT ) Maximum I EXT = 10 A (ac) (R A <20 Ω)
General Specifications
Display 1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlight
User Interface Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, Water and Dust Resistant Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory Internal memory storage up to 1500 records accessible via USB port
Dimensions 9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)
Weight 2.43 lbs (1.1 kg) including batteries
16.8 lbs (7.6 kg) included accessories and batteries in carrying case